DOI 10.1161/hypertensionaha.124.22790
Coronary and Systemic Vasodilator Responsiveness of Patients Receiving Conventional Intermittent or Nocturnal Hemodialysis.
Аннотация
BACKGROUND
Nocturnal hemodialysis (nHD) restores the attenuated brachial artery vasodilator responsiveness of patients receiving conventional intermittent hemodialysis (iHD). Its impact on coronary vasodilatation is unknown.
METHODS
We evaluated 25 patients on hemodialysis who fulfilled transplant criteria: 15 on iHD (4-hour sessions, 3 d/wk) and 10 on nHD (≈40 h/wk over 8-10-hour sessions) plus 6 control participants. Following diagnostic angiography, left anterior descending (LAD) coronary flow reserve and mean luminal diameter were quantified at baseline and during sequential intracoronary administration of adenosine (infusion and bolus), nitroglycerin (bolus), acetylcholine (infusion), acetylcholine coinfused with vitamin C, and, finally, sublingual nitroglycerin.
RESULTS
Coronary flow reserve in those receiving nHD was augmented relative to iHD (3.28±0.26 versus 2.17±0.12 [mean±SEM]; P<0.03) but attenuated, relative to controls (4.80±0.63; P=0.011). Luminal dilatations induced by intracoronary adenosine and nitroglycerin were similar in nHD and controls but blunted in the iHD cohort (P<0.05 versus both). ACh elicited vasodilatation in controls but constriction in both dialysis groups (both P<0.05, versus control); vitamin C coinfusion had no effect. Sublingual nitroglycerin increased mid-left anterior descending diameter and reduced mean arterial pressure in controls (+15.2±2.68%; -16.00±1.60%) and in nHD recipients (+14.78±5.46%; -15.82±1.32%); iHD responses were markedly attenuated (+1.9±0.86%; -5.89±1.41%; P<0.05, all comparisons).
CONCLUSIONS
Coronary and systemic vasodilator responsiveness to both adenosine and nitroglycerin is augmented in patients receiving nHD relative to those receiving iHD, whereas vasoconstrictor responsiveness to acetylcholine does not differ. By improving coronary conduit and microvascular function, nHD may reduce the cardiovascular risk of patients on dialysis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.