MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1748-605x/ac19bf

Медицинская библиотека · Biomedical materials (Bristol, England) · 2021

Blood compatibility evaluations of CaCO3particles.

Lin Jiansheng, Huang Linghong, Xiang Rong, Ou Haibo, Li Xinhua, Chen An, Liu Zonghua

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

CaCO3particles, due to their unique properties such as biodegradation, pH-sensitivity, and porous surface, have been widely used as carrier materials for delivering drugs, genes, vaccines, and other bioactive molecules. In these applications, CaCO3particles are often administered intravenously. In this sense, the interaction between CaCO3particles and blood components plays a key role in their delivery efficacy and biosafety, though the hemocompatibility of CaCO3particles has not been evaluated until now. Deficiency in the biosafety information has delayed the clinical use of CaCO3particles in delivery systems. In this work, we investigated the biosafety of CaCO3particles, focusing on theirin vitroandin vivoeffects on key blood components (red blood cells, platelets, etc) and coagulation functions. We foundin vitrothat high concentrations of CaCO3particles can cause the aggregation and hemolysis of red blood cells, with platelet activation and coagulation prolongation.In vivo, we found that intravenously injected CaCO3particles at 50 mg kg-1significantly disturbed the red blood cells, and platelet-related blood routine indexes, but did not induce visible abnormalities in the tissue structures of the key organs. Overall, these effects may be due to the enormous adsorption capability of the porous surface of CaCO3particles. 0.1 mg ml-1of the CaCO3particles exhibit excellent compatibility for their practical applications. These results would be expected to greatly promote thein vivoapplications and clinical use of CaCO3particles in biomedicine.

Для цитирования: Lin Jiansheng, Huang Linghong, Xiang Rong, Ou Haibo, Li Xinhua, Chen An, Liu Zonghua. Blood compatibility evaluations of CaCO3particles.. Biomedical materials (Bristol, England). 2021. DOI: 10.1088/1748-605x/ac19bf.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.