DOI 10.1038/s41372-024-02062-7
Continuous improvement of non-emergent neonatal intubations in a level IV NICU.
Аннотация
OBJECTIVE
We sought to improve practices and outcomes related to non-emergent neonatal intubations in a level IV academic Neonatal Intensive Care Unit.
STUDY
DESIGN
A multidisciplinary team created guidelines for non-emergent neonatal intubations. In period 1, premedication practices were standardized. In period 2, paralytic use and video laryngoscope use were recommended. Premedication and video laryngoscopy practices were assessed along with number of intubation attempts and frequency of bradycardia and desaturation.
RESULTS
636 intubations performed by neonatology fellows and neonatal advanced practice providers were reviewed over six academic years. Two academic years were included in each of the following study periods: baseline, period 1, and period 2. In our unit, compliance with recommended premedication practices and administration of paralytic medication has increased considerably, and video laryngoscopy is now utilized in most of our procedures. The frequency of intubation success on the first attempt has increased, and the frequency of both bradycardia and desaturation during intubation has decreased. In our analysis, paralytic use (AOR 2.41, 95 CI (1.53, 3.81)) and the combination of paralytic and video laryngoscopy (AOR 4.07, 95 CI (2.09, 7.92)) are associated with increased odds of intubating successfully on the first attempt.
CONCLUSIONS
This initiative increased the use of standardized premedication, paralytic medication and video laryngoscopy for non-emergent neonatal intubations with temporally associated improvement in patient outcomes including fewer intubation attempts and reduction in physiologic instability.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.