m+Medelevator.RU
← Поиск публикаций
Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2011

Hammering sound frequency analysis and prevention of intraoperative periprosthetic fractures during total hip arthroplasty.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sakai Rina, Kikuchi Aki, Morita Towa, Takahira Naonobu, Uchiyama Katsufumi, Yamamoto Takeaki, Moriya Mistutoshi, Uchida Kentaro, Fukushima Kensuke, Tanaka Kensei, Takaso Masashi, Itoman Moritoshi, Mabuchi Kiyoshi

Аннотация

Adequate fixation at the time of cementless stem implantation depends on the operator's experience. An objective evaluation method to determine whether the stem has been appropriately implanted may be helpful. We studied the relationship between the hammering sound frequency during stem implantation and internal stress in a femoral model, and evaluated the possible usefulness of hammering sound frequency analysis for preventing intraoperative fracture. Three types of cementless stem (BiCONTACT®, SL-PLUS®, and AI-Hip®) were used. Surgeons performed stem insertion using a procedure similar to that employed in a routine operation. Stress was estimated by finite element analysis, the hammering force was measured, and frequency analysis of hammering sound data obtained using a microphone. Finite element analysis showed a decrease in the hammering sound frequency with an increase in the estimated maximum stress. When a decrease in frequency was observed, adequate hammering had occurred, and the continuation of hammering risked fracture. Based on the relationship between stress and frequency, the evaluation of changes in frequency may be useful for preventing the development of intraoperative fractures. Using our method, when a decrease in frequency is observed, the hammering force should be reduced. Hammering sound frequency analysis may allow the prediction of bone fractures that can be visually confirmed, and may be a useful objective evaluation method for the prevention of intraoperative periprosthetic fractures during stem insertion.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты