MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aog.0000000000000424

Медицинская библиотека · Obstetrics and gynecology · 2014

Diagnostic accuracy of fetal heart rate monitoring in the identification of neonatal encephalopathy.

Graham Ernest M, Adami Rebecca R, McKenney Stephanie L, Jennings Jacky M, Burd Irina, Witter Frank R

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To estimate the diagnostic accuracy of electronic fetal heart rate abnormalities in the identification of neonates with encephalopathy treated with whole-body hypothermia.

METHODS

Between January 1, 2007, and July 1, 2013, there were 39 neonates born at two hospitals within our system treated with whole-body hypothermia within 6 hours of birth. Neurologically normal control neonates were matched to each case by gestational age and mode of delivery in a two-to-one fashion. The last hour of electronic fetal heart rate monitoring before delivery was evaluated by three obstetricians blinded to outcome.

RESULTS

The differences in tracing category were not significantly different (neonates in the case group 10.3% I, 76.9% II, 12.8% III; neonates in the control group 9.0% I, 89.7% II, 1.3% III; P=.18). Bivariate analysis showed neonates in the case group had significantly increased late decelerations, total deceleration area 30 (debt 30) and 60 minutes (debt 60) before delivery and were more likely to be nonreactive. Multivariable logistic regression showed neonates in the case group had a significant decrease in early decelerations (P=.03) and a significant increase in debt 30 (.01) and debt 60 (P=.005). The area under the receiver operating characteristic curve, sensitivity, and specificity were 0.72, 23.1%, and 94.9% for early decelerations; 0.66, 33.3%, and 87.2% for debt 30, and 0.68, 35.9%, and 89.7% for debt 60, respectively.

CONCLUSION

Abnormalities during the last hour of fetal heart rate monitoring before delivery are poorly predictive of neonatal hypoxic-ischemic encephalopathy qualifying for whole-body hypothermia treatment within 6 hours of birth. LEVEL OF EVIEDENCE: II.

Для цитирования: Graham Ernest M, Adami Rebecca R, McKenney Stephanie L, Jennings Jacky M, Burd Irina, Witter Frank R. Diagnostic accuracy of fetal heart rate monitoring in the identification of neonatal encephalopathy.. Obstetrics and gynecology. 2014. DOI: 10.1097/aog.0000000000000424.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.