MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.0529-567x.2018.05.005

Медицинская библиотека · Zhonghua fu chan ke za zhi · 2018

[Role of BoBs technology in early missed abortion chorionic villi].

Li Z Y, Liu X Y, Peng P, Chen N, Ou J, Hao N, Zhou J, Bian X M

СтатьяПеревод в очереди

Аннотация

Objective

To investigate the value of bacterial artificial chromosome-on-beads (BoBs) technology in the genetic analysis of early missed abortion chorionic villi.

Methods

Early missed abortion chorionic villi were detected with both conventional karyotyping method and BoBs technology in Peking Union Medical Hospital from July 2014 to March 2015. Compared the results of BoBs with conventional karyotyping analysis to evaluate the sensitivity, specificity and accuracy of this new method.

Results

(1) A total of 161 samples were tested successfully in the technology of BoBs, 131 samples were tested successfully in the method of conventional karyotyping. (2) All of the cases obtained from BoBs results in (2.7±0.6) days and obtained from conventional karyotyping results in (22.5±1.9) days. There was significant statistical difference between the two groups (t=123.315, P<0.01) . (3) Out of 161 cases tested in BoBs, 85 (52.8%, 85/161) cases had the abnormal chromosomes, including 79 cases chromosome number abnormality, 4 cases were chromosome segment deletion, 2 cases mosaic. Out of 131 cases tested successfully in conventional karyotyping, 79 (60.3%, 79/131) cases had the abnormal chromosomes including 62 cases chromosome number abnormality, 17 cases other chromosome number abnormality, and the rate of chromosome abnormality between two methods was no significant differences (P=0.198) . (4) Conventional karyotyping results were served as the gold standard, the accuracy of BoBs for abnormal chromosomes was 82.4% (108/131) , analysed the normal chromosomes (52 cases) and chromosome number abnormality (62 cases) tested in conventional karyotyping, the accuracy of BoBs for chromosome number abnormality was 94.7% (108/114) .

Conclusion

BoBs is a rapid reliable and easily operated method to test early missed abortion chorionic villi chromosomal abnormalities.

Для цитирования: Li Z Y, Liu X Y, Peng P, Chen N, Ou J, Hao N, Zhou J, Bian X M. [Role of BoBs technology in early missed abortion chorionic villi].. Zhonghua fu chan ke za zhi. 2018. DOI: 10.3760/cma.j.issn.0529-567x.2018.05.005.