MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13019-026-04191-w

Медицинская библиотека · Journal of cardiothoracic surgery · 2026

Post-LVAD diuretic trajectories and predictors of diuretic resistance.

Borović Saša, Kosević Dragana, Nesković Jelena Stefanović, Akay Mehmet Hakan, Petrović Jovan, Dabić Petar, Rineiska Nadiia, Bojić Milovan

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Renal dysfunction and diuretic resistance may persist or develop after left ventricular assist device (LVAD) implantation despite restoration of cardiac output (CO). This study aimed to characterize post-LVAD diuretic trajectories and identify hemodynamic predictors of diuretic resistance or diuretic de-escalation in patients receiving ≤ 160 mg versus > 160 mg of furosemide prior to implantation.

METHODS

In this retrospective, single-center observational study, 39 patients with advanced heart failure (79.5% male; median age 58 [53; 64] years) who underwent implantation of a HeartMate 3 LVAD as a bridge to transplantation between December 2017 and March 2024 were included. Pre-implant clinical, laboratory, echocardiographic, and invasive hemodynamic parameters were analysed according to baseline diuretic dose and subsequent changes in diuretic requirements following LVAD implantation.

RESULTS

Patients receiving > 160 mg/day of furosemide (31%) had significantly higher right atrial pressure (p = 0.006), higher mean pulmonary artery pressure (p = 0.028), and lower pulmonary artery pulsatility index (PAPi; p = 0.004) compared with those receiving ≤ 160 mg/day. Among low-dose patients, 33% developed post-LVAD diuretic resistance, associated with lower PAPi and higher CO. In multivariate analysis, lower PAPi independently predicted diuretic resistance (OR 0.82, 95% CI 0.69-0.98; p = 0.027), while higher CO was also associated with increased risk (OR 3.09, 95% CI 1.25-7.59; p = 0.014). PAPi demonstrated significant inverse discrimination for diuretic resistance (AUC 0.26; p = 0.005). Kaplan-Meier analysis showed reduced event-free survival in patients with PAPi ≤ 1.85 (log-rank p = 0.022).

CONCLUSION

Despite normalization of CO after LVAD implantation, diuretic resistance may persist or emerge in the setting of right ventricular - pulmonary uncoupling. Low pre-implant PAPi and venous congestion appear central to impaired renal response, highlighting the importance of comprehensive right-sided hemodynamic assessment during LVAD candidate evaluation.

Для цитирования: Borović Saša, Kosević Dragana, Nesković Jelena Stefanović, Akay Mehmet Hakan, Petrović Jovan, Dabić Petar, Rineiska Nadiia, Bojić Milovan. Post-LVAD diuretic trajectories and predictors of diuretic resistance.. Journal of cardiothoracic surgery. 2026. DOI: 10.1186/s13019-026-04191-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.