MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2018.03.044

Медицинская библиотека · The Journal of hand surgery · 2018

Ideal Starting Point and Trajectory of a Screw for the Dorsal Approach to Scaphoid Fractures.

Kupperman Asher, Breighner Ryan, Saltzman Eliana, Sneag Darryl, Wolfe Scott, Lee Steve

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine the screw starting point and trajectory for the dorsal approach to scaphoid fractures that provides a combination of length and compression at the fracture site.

METHODS

Computed tomography scans were obtained of 10 scaphoid fractures for 3 common fracture types. A computerized model was generated for each scaphoid. Screw starting point, length, and angle to the fracture plane were analyzed for starting points and trajectories within a safe zone that protected against cortical penetration. A novel analysis was developed to assess a combination of screw length and angle to fracture plane, termed "effective compression length" (ECL). ECL assessed the screw working distance perpendicular to the fracture. Results were analyzed to determine optimal screw starting point and trajectory.

RESULTS

For proximal pole fractures, a screw perpendicular to the fracture was 9.7 mm from the longitudinal axis starting point (LASP). The screw with the largest ECL was 6.8 mm from the LASP, crossing the fracture at a 67° obliquity. For waist fractures, a perpendicular screw was 7.8 mm from the LASP. The screw with the largest ECL was 6.0 mm away, crossing the fracture at 74°. For distal oblique fractures, a perpendicular screw was 10.2 mm from the LASP. The screw with the largest ECL was 6.4 mm away, crossing the fracture at 70°. A screw with the classic starting point and trajectory crossed the fracture at obliquities of 48°, 51°, and 45° for proximal, waist, and distal fractures, respectively.

CONCLUSIONS

Scaphoid screws placed with the classic starting point and trajectory cross the fracture at an obliquity. By altering the screw starting point and trajectory, screws with adequate length will be more perpendicular to the fracture plane.

CLINICAL RELEVANCE: Screw starting point and trajectory for scaphoid fractures may be altered based on fracture type to obtain a long screw that is closer to perpendicular to the fracture.

Для цитирования: Kupperman Asher, Breighner Ryan, Saltzman Eliana, Sneag Darryl, Wolfe Scott, Lee Steve. Ideal Starting Point and Trajectory of a Screw for the Dorsal Approach to Scaphoid Fractures.. The Journal of hand surgery. 2018. DOI: 10.1016/j.jhsa.2018.03.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.