MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transci.2021.103262

Медицинская библиотека · Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis · 2021

ABO antibody titer performance characteristics and correlates between two automated platforms.

Corean Jessica, Gilsdorf Jonella, Sauter Jessi, Pamukcu Pette, Thorpe Steve, Pham Tho

СтатьяПеревод в очереди

Аннотация

BACKGROUND

AABB standards require a policy for assessing transfusing ABO-incompatible plasma. After a fatal hemolytic event with incompatible plasma, our institution instituted platelet donor population titer method for ABO antibodies on the PK7300, with high-titer being defined as having isohemagglutinin titers greater than 256. We recently switched titering platforms to the Neo Iris and we seek to determine the equivalent isohemagglutinin high-titer cutoff on the Neo Iris as compared to the PK7300.

METHODS

We measured the titers on 299 apheresis platelet donors and compared its performance characteristics at various cutoffs to the PK7300 reference standard. Discrepant results were manually diluted and retested on the Neo Galileo. Furthermore, since the Neo Iris is able to determine isotype and antigen specific titers, we also characterized these features in our donor population.

RESULTS

IgM titer of 128 on the Neo Iris has better accuracy compared to the titer of 64 (94 % vs 93.6 %). Eleven of sixteen discordant results were in agreement with Neo Iris. Blood group O had the highest IgG antibody titers for both anti-A and anti-B (p = 8.4E-17 and 4.3E-09, respectively). Additionally, group O donors exhibited lower anti-A2 than anti-A1 IgG titers.

DISCUSSION: The Neo Iris titer cut-off of 128 had the best overall accuracy and correlation with a 256 cut-off on our laboratory developed test on the PK7300 platform. Additionally, we found that group O donors had the highest titer antibodies, with typically higher IgG titers than IgM, and generally multiple dilution levels greater than other blood types.

Для цитирования: Corean Jessica, Gilsdorf Jonella, Sauter Jessi, Pamukcu Pette, Thorpe Steve, Pham Tho. ABO antibody titer performance characteristics and correlates between two automated platforms.. Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis. 2021. DOI: 10.1016/j.transci.2021.103262.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.