m+Medelevator.RU
← Поиск публикаций
Narra J · 2026

Comparison of interleukin-6 and serum creatinine levels in preeclampsia and normal pregnancy patients: A cross-sectional study in Indonesia.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dewi Syerli R, Yeni Cut M, Munizar Munizar, Dewi Tgk Puspa, Utami Niken A, Rusnaidi Rusnaidi

Аннотация

Preeclampsia (PE) is a complication of pregnancy with high morbidity and mortality, characterized by endothelial dysfunction, systemic inflammation, and impaired renal function. Interleukin-6 (IL-6) and serum creatinine have potential as biomarkers for early detection of PE; however, data from Indonesia are limited. The aim of this study was to compare IL-6 and serum creatinine levels between pregnant women with PE and normotensive controls, as well as their diagnostic performance in identifying PE. A cross-sectional study involving pregnant women with PE and normotensive controls was conducted at Dr. Zainoel Abidin Hospital, Banda Aceh, Indonesia. Serum IL-6 and creatinine levels were measured using the ECLIA method. Levels were compared using the Mann-Whitney test; diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis, and multivariable logistic regression was used to evaluate combined diagnostic contribution. A total of 68 pregnant women were included, comprising 34 patients with PE and 34 normotensive controls. Median IL-6 levels were significantly higher in the PE group (16.05 pg/mL) than in the control group (3.71 pg/mL). Receiver operating characteristic analysis demonstrated excellent diagnostic performance of IL-6, with an are under the curve (AUC) of 0.831 (95%CI: 0.734-0.929). At an optimal cutoff value of 5.52 pg/mL, IL-6 achieved a sensitivity of 73.53%, specificity of 76.47%, and diagnostic accuracy of 86.76%. Median serum creatinine levels were also significantly elevated in the PE group (0.56 mg/dL) compared with controls (0.44 mg/dL; p < 0.001). The AUC for serum creatinine was 0.806 (95%CI: 0.700-0.912), indicating good diagnostic performance. At a cutoff value of 0.475 mg/dL, serum creatinine demonstrated a sensitivity of 70.59%, specificity of 73.53%, and accuracy of 72.06%. Multivariable logistic regression confirmed that IL-6 (B = 0.123; p = 0.005) and serum creatinine (B = 9.306; p = 0.023) were independently associated with PE, explaining 57.5% of PE variability (Nagelkerke R2 = 0.575). These findings indicate that serum IL-6 and creatinine are significantly associated with PE, and their combined assessment shows potential as a predictive biomarker with good diagnostic performance.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты