DOI 10.33963/kp.14811

Медицинская библиотека · Kardiologia polska · 2019

Pol-CDRIE registry - 1-year observational data on patients hospitalized due to cardiac device-related infective endocarditis in Polish referential cardiology centres.

Płońska-Gościniak Edyta, Olędzki Szymon, Kukulski Tomasz, Kosmala Wojciech, Młynarski Rafał, Oko-Sarnowska Zofia, Wojtkowska Agnieszka, Gościniak Piotr, Gąsior Zbigniew, Hryniewiecki Tomasz, Boczar Krzysztof, Daniłowicz-Szymanowicz Ludmiła, Kempa Maciej, Jaroch Joanna, Nowalany-Kozielska Ewa, Lisowska Anna, Mizia-Stec Katarzyna, Sinkiewicz Władysław, Świątkiewicz Iwona, Szyszka Andrzej, Kosior Dariusz, Kasprzak Jarosław D

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The rate of cardiac device-related infective endocarditis (CDRIE) is increasing worldwide, but no detailed data are available for Poland.

AIMS: We aimed to evaluate clinical, diagnostic, and therapeutic data of patients hospitalized due to CDRIE in 22 Polish referential cardiology centers from May 1, 2016 to May 1, 2017.

METHODS

Participating cardiology departments were asked to fill in a questionnaire that included data on the number of hospitalized patients, number and types of implanted cardiac electrotherapy devices, and number of infective endocarditis cases. We also collected clinical data and data regarding the management of patients with CDRIE.

RESULTS

Overall, 99 621 hospitalizations were reported. Infective endocarditis unrelated to cardiac device was the cause of 596 admissions (0.6%), and CDRIE, of 195 (0.2%). Pacemaker was implanted in 91 patients with CDRIE (47%); cardioverter‑defibrillator, in 51 (26%); cardiac resynchronization therapy‑defibrillator, in 48 (25%); and cardiac resynchronization therapy‑pacemaker, in 5 (2.5%). The most common symptoms were malaise (62%), fever/chills (61%), cough (21%), chest pain (19.5%), and inflammation of the device pocket (5.6%). Cultures were positive in 77.5% of patients. The cardiac device was removed in 91% of patients. The percutaneous approach was most common for cardiac device removal. All patients received antibiotic therapy, and 3 patients underwent a heart valve procedure. Transesophageal echocardiography was performed in 80% of patients. The most common complication was heart failure (25% of patients).

CONCLUSIONS

The clinical profile, pathogen types, and management strategies in Polish patients with CDRIE are consistent with similar data from other European countries. Transesophageal echocardiography was performed less frequently than recommended. The removal rate in the Polish population is consistent with the general rates observed for interventional treatment in patients with CDRIE.

Для цитирования: Płońska-Gościniak Edyta, Olędzki Szymon, Kukulski Tomasz, Kosmala Wojciech, Młynarski Rafał, Oko-Sarnowska Zofia, Wojtkowska Agnieszka, Gościniak Piotr, Gąsior Zbigniew, Hryniewiecki Tomasz, Boczar Krzysztof, Daniłowicz-Szymanowicz Ludmiła, Kempa Maciej, Jaroch Joanna, Nowalany-Kozielska Ewa, Lisowska Anna, Mizia-Stec Katarzyna, Sinkiewicz Władysław, Świątkiewicz Iwona, Szyszka Andrzej, Kosior Dariusz, Kasprzak Jarosław D. Pol-CDRIE registry - 1-year observational data on patients hospitalized due to cardiac device-related infective endocarditis in Polish referential cardiology centres.. Kardiologia polska. 2019. DOI: 10.33963/kp.14811.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.