OBJECTIVE

The purpose of this study was to determine whether an occiput posterior (OP) fetal head position increases the risk for anal sphincter injury when compared with an occiput anterior (OA) position in vacuum-assisted deliveries.

STUDY

DESIGN

We conducted a retrospective cohort study of 393 vacuum-assisted singleton vaginal deliveries. Maternal demographics and obstetric and neonatal data were collected from an obstetric database and chart review.

RESULTS

Within the OP group, 41.7% developed a third- or fourth-degree laceration compared with 22.0% in the OA group (OR 2.5, 95% CI 1.4-4.7). In a logistic regression model that controlled for BMI, race, nulliparity, length of second stage, episiotomy, birth weight, head circumference, and fetal head position, OP position was 4.0 times (95% CI 1.7-9.6) more likely to be associated with an anal sphincter injury than OA position.

CONCLUSION

Among vacuum deliveries, an OP head position confers an incrementally increased risk for anal sphincter injury over an OA position.

Для цитирования: Wu Jennifer M, Williams Kathryn S, Hundley Andrew F, Connolly AnnaMarie, Visco Anthony G. Occiput posterior fetal head position increases the risk of anal sphincter injury in vacuum-assisted deliveries.. American journal of obstetrics and gynecology. 2005. DOI: 10.1016/j.ajog.2005.03.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.