Outcomes among patients bridged to heart transplant with microaxial flow versus durable left ventricular assist device support.
Аннотация
OBJECTIVE
To evaluate characteristics and outcomes of patients bridged to orthotopic heart transplantation with microaxial left ventricular assist device (ma-LVAD) versus durable LVAD (d-LVAD).
METHODS
This was a single-center retrospective cohort study in which characteristics outcomes of patients undergoing orthotopic heart transplantation between May 2019 and May 2024 who were bridged with ma-LVAD versus d-LVAD, were compared.
RESULTS
Over the study period, the percentage of patients bridged with ma-LVAD increased from 0% to 20%. Patients bridged with d-LVAD were more likely to have history of hypertension (80% vs 65%; P = .03), a higher body mass index (32.53 vs 28.15; P < .0001), and anti-human leukocyte antigens antibodies (54% vs 36%; P = .02) before transplant, otherwise groups were similar in their baseline characteristics. Unadjusted Kaplan-Meier analysis demonstrated no difference in survival between these 2 bridging strategies. However, postoperative blood product use (3 vs 0 units; P < .0001), moderate or severe primary graft dysfunction (27% vs 14%; P = .04), and delayed sternal closure (45% vs 9%; P < .0001) were all higher among those bridged with d-LVAD versus ma-LVAD. Rejection on the first postoperative biopsy was reported in a 60% in the d-LVAD group versus 33% in the ma-LVAD group (P = .0006). Postoperative intensive care unit (7 vs 6 days; P = .03) and overall postoperative length of stay (17 vs 12 days; P = .002) were greater in patients bridged with d-LVAD versus ma-LVAD, respectively.
CONCLUSIONS
The use of ma-LVAD compared with d-LVAD as a bridging strategy was not associated with differences in survival. However, bridging with ma-LVAD compared with d-LVAD was associated with lower morbidity after orthotopic heart transplantation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.