PURPOSE: To describe effects of sustained-release steroid delivery devices on intraocular pressure (IOP) in eyes with glaucoma drainage devices.

METHODS

Retrospective case series of eyes with steroid implants (dexamethasone or fluocinolone acetonide) and prior glaucoma drainage devices (Ahmed, Baerveldt) without uveitis. Outcomes included IOP, IOP rise, central foveal thickness, and IOP medications.

RESULTS

We included 14 eyes (14 patients, 38% men, 94% pseudophakic). Mean age at steroid implantation was 64 ± 12 years. Baerveldt (64%) was more common than Ahmed (36%). Tubes were in the anterior chamber (57.1%), sulcus (28.6%), and pars plana (14.3%). Ozurdex (93%) was more common than Yutiq (7%). Mean IOP was 13.5 ± 3.4 mmHg preimplant, 11.8 ± 3.7 mmHg at month 1, 13.3 ± 3.6 mmHg at month 3 ( P = 0.35), and 11.3 ± 3.8 mmHg at 1 year ( P = 0.032). Mean antihypertensive medication was unchanged at month 3 ( P = 1.0) and -0.36 medication at last follow-up ( P = 0.35). Mean central foveal thickness change was -204 ± 158 µ m ( P = 0.001). There were no cases of endophthalmitis.

CONCLUSION

Intravitreal steroid implants were safe and effective for the treatment of postsurgical CME in patients with pre-existing glaucoma drainage devices. There was no increase in IOP and no increase in antihypertensive drops.

Для цитирования: Zhou Henry W, Tandias Rachel, Lu Edward S, Hoyek Sandra, Lin Michael M, Miller John B, Valle David Solá-Del, Patel Nimesh A. INTRAVITREAL SUSTAINED RELEASE STEROID IMPLANTS ARE SAFE AND EFFECTIVE IN PATIENTS WITH GLAUCOMA DRAINAGE DEVICES.. Retina (Philadelphia, Pa.). 2025. DOI: 10.1097/iae.0000000000004396.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.