Venous blood gas parameters, electrolytes, glucose and lactate concentration in sick neonatal foals: Direct venipuncture versus push-pull technique.
СтатьяObservational Study, VeterinaryНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Del Prete Chiara, Lanci Aliai, Cocchia Natascia, Freccero Francesca, Di Maio Chiara, Castagnetti Carolina, Mariella Jole, Micieli Fabiana
Аннотация
BACKGROUND: Blood collection by indwelling intravenous catheter (IVC) avoids repeated venipuncture, which could cause thrombophlebitis risk, anxiety and pain in patients.
OBJECTIVES: To compare blood gas parameters, electrolytes, glucose, lactate and haematocrit concentration obtained from venous blood samples collected via a jugular IVC by push-pull (PP) technique to those obtained by venipuncture in hospitalised foals, at the time of catheter placement (T0) and 24 hours after the beginning of intravenous therapy (T24).
STUDY DESIGN: Prospective observational study.
METHODS: Paired blood samples were drawn from hospitalised foals at T0 and T24. In each foal, one venous blood sample was collected via IVC by the following PP technique: 2.4 mL of blood was aspirated and immediately reinfused through the catheter three times consecutively, then 1 mL of blood was collected using a 1 mL heparinised syringe. Thereafter, another sample was collected by direct venipuncture of the contralateral jugular vein, with an identical 1 mL heparinised syringe, with a 1-inch, 20-G needle. All samples were analysed with an automated blood gas analyser within 10 minutes of collection. The agreement between the two techniques was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC).
RESULTS: The level of agreement of blood gas values obtained by the two different techniques was high with very small bias and clinically acceptable ICC (>0.907 at T0; >0.794 at T24) for all variables, except for haematocrit (bias -3.52 at T0; -2.44 at T24) and PvO2 at T0 and T24 (ICC 0.669 and 0.733, respectively).
MAIN LIMITATIONS: Potential sub-clinical catheter-related complications were not investigated by ultrasound or bacterial culture of the catheter; short duration of the study.
CONCLUSIONS: PP technique appears to be acceptable for collection of blood samples for venous blood gas parameters, as well as electrolytes, glucose and lactate in sick neonatal foals.
OBJECTIVES: To compare blood gas parameters, electrolytes, glucose, lactate and haematocrit concentration obtained from venous blood samples collected via a jugular IVC by push-pull (PP) technique to those obtained by venipuncture in hospitalised foals, at the time of catheter placement (T0) and 24 hours after the beginning of intravenous therapy (T24).
STUDY DESIGN: Prospective observational study.
METHODS: Paired blood samples were drawn from hospitalised foals at T0 and T24. In each foal, one venous blood sample was collected via IVC by the following PP technique: 2.4 mL of blood was aspirated and immediately reinfused through the catheter three times consecutively, then 1 mL of blood was collected using a 1 mL heparinised syringe. Thereafter, another sample was collected by direct venipuncture of the contralateral jugular vein, with an identical 1 mL heparinised syringe, with a 1-inch, 20-G needle. All samples were analysed with an automated blood gas analyser within 10 minutes of collection. The agreement between the two techniques was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC).
RESULTS: The level of agreement of blood gas values obtained by the two different techniques was high with very small bias and clinically acceptable ICC (>0.907 at T0; >0.794 at T24) for all variables, except for haematocrit (bias -3.52 at T0; -2.44 at T24) and PvO2 at T0 and T24 (ICC 0.669 and 0.733, respectively).
MAIN LIMITATIONS: Potential sub-clinical catheter-related complications were not investigated by ultrasound or bacterial culture of the catheter; short duration of the study.
CONCLUSIONS: PP technique appears to be acceptable for collection of blood samples for venous blood gas parameters, as well as electrolytes, glucose and lactate in sick neonatal foals.