DOI 10.1016/j.earlhumdev.2010.06.011
Intratracheal catheter suction removes the same volume of meconium with less impact on desaturation compared with meconium aspirator in meconium aspiration syndrome.
Аннотация
OBJECTIVE
To evaluate the impact of suction technique on the rate of meconium removal, oxygenation, and hemodynamics in an animal experimental model of meconium aspiration syndrome (MAS).
METHODS
MAS was induced in ventilated rabbits using 3.5 ml/kg of 20% human meconium. Tracheal suction with either catheter suction (CS) or meconium aspirator (MA) was performed after meconium instillation. Percentage of meconium collection rate, PaO(2) trends for 2h after tracheal suction, and acute-phase SpO(2) trends were compared between CS and the other three groups, the tube was withdrawn while meconium was aspirated with an MA, then the trachea was reintubated 5, 10 or 15s after suctioning of meconium.
RESULTS
Percentage of meconium collection rate and PaO(2) showed no significant differences between groups. The MA group taking 15s for reintubation after meconium suctioning, showed a significantly lower acute-phase SpO(2) than the CS group (P<0.05). The time for SpO(2) to return to >or=90% was also longer in the MA group taking 15s for reintubation than in the CS group (P<0.05).
CONCLUSION
Intratracheal CS removed the same volume of meconium with less impact on desaturation compared with meconium aspiration in an animal model of MAS. Intratracheal CS may be benefit to remove meconium in non-vigorous infants with meconium-stained amniotic fluid at birth.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.