MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.125.044790

Медицинская библиотека · Journal of the American Heart Association · 2026

Patient-Specific Computational Flow Simulation Reveals Adverse Hemodynamic Factors Associated With Occlusion of Directional Branches After Fenestrated-Branched Endovascular Aneurysm Repair.

Tran Kenneth, Chait Jesse, Tenorio Emmanuel, Yang Weiguang, Marsden Alison, Mendes Bernardo, Lee Jason T, Oderich Gustavo S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Fenestrated and branched endovascular aneurysm repair can be complicated by branch vessel occlusion in the absence of structural stenosis. We hypothesized that computational flow simulation could identify adverse hemodynamic features associated with postfenestrated and branched endovascular aneurysm repair branch occlusion.

METHODS

Patients undergoing 4-vessel fenestrated and branched endovascular aneurysm repair for Extent II to IV thoracoabdominal aortic aneurysms were retrospectively reviewed. Branches that occluded without identifiable kinking or stenosis on computed tomography were included, along with an equal cohort of anatomy-matched patent controls. Patient-specific pulsatile rigid-wall simulations were performed using SimVascular with individualized geometries and boundary conditions. Abnormal time-averaged wall shear stress (TAWSS) was defined as <10 or >70 dynes/cm2.

RESULTS

Nine patients (36 target vessels) experienced 10 branch occlusions. Postoperative pressure and flow did not differ significantly between occluded and patent renal or mesenteric branches. However, occluded renal and mesenteric branches demonstrated significantly larger postoperative areas of abnormal TAWSS compared with controls (renal: 14.5% versus 5.9%, P=0.003; mesenteric: 17.7% versus 9.9%, P=0.035). Logistic generalized estimating equation modeling showed abnormal TAWSS to be a significant predictor of renal branch occlusion (P=0.0085). Model estimates suggested occlusion probabilities of 1.1%, 31%, and 94% at 0%, 10%, and 20% abnormal TAWSS surface area, respectively. A cluster-bootstrapped receiver operating characteristic curve (area under the curve, 0.876) identified a >10.2% threshold that correctly classified 92% of renal occlusions. Abnormal TAWSS frequently localized to distal stent-artery interfaces.

CONCLUSIONS

Elevated abnormal TAWSS within stented renal branches is associated with subsequent branch occlusion after fenestrated and branched endovascular aneurysm repair. Computational flow simulation-derived TAWSS thresholds may help identify high-risk branches before failure, warranting prospective validation.

Для цитирования: Tran Kenneth, Chait Jesse, Tenorio Emmanuel, Yang Weiguang, Marsden Alison, Mendes Bernardo, Lee Jason T, Oderich Gustavo S. Patient-Specific Computational Flow Simulation Reveals Adverse Hemodynamic Factors Associated With Occlusion of Directional Branches After Fenestrated-Branched Endovascular Aneurysm Repair.. Journal of the American Heart Association. 2026. DOI: 10.1161/jaha.125.044790.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.