Pregnancy related complications in women with hypertrophic cardiomyopathy.
Аннотация
OBJECTIVES
To determine whether pregnancy is well tolerated in hypertrophic cardiomyopathy.
SETTING
Referral clinic.
DESIGN
The study cohort comprised 127 consecutively referred women with hypertrophic cardiomyopathy. Forty (31.5%) underwent clinical evaluation before pregnancy. The remaining 87 (68.5%) were referred after their first pregnancy. All underwent history, examination, electrocardiography, and echocardiography. Pregnancy related symptoms and complications were determined by questionnaire and review of medical and obstetric records where available.
RESULTS
There were 271 pregnancies in total. Thirty six (28.3%) women reported cardiac symptoms in pregnancy. Over 90% of these women had been symptomatic before pregnancy. Symptoms deteriorated during pregnancy in fewer than 10%. Of the 36 women with symptoms during pregnancy, 30 had further pregnancies. Symptoms reoccurred in 18 (60%); symptomatic deterioration was not reported. Heart failure occurred postnatally in two women (1.6%). No complications were reported in 19 (15%) women who underwent general anaesthesia and in 22 (17.4%) women who received epidural anaesthesia, three of whom had a significant left ventricular outflow tract gradient at diagnosis after pregnancy. Three unexplained intrauterine deaths occurred in women taking cardiac medication throughout pregnancy. No echocardiographic or clinical feature was a useful indicator of pregnancy related complications.
CONCLUSIONS
Most women with hypertrophic cardiomyopathy tolerate pregnancy well. However, rare complications can occur and therefore planned delivery and fetal monitoring are still required for some patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.