BACKGROUND

Intracardiac injuries caused by needles are rare and typically require removal via median sternotomy or limited thoracotomy. We present a case of successful removal using a totally endoscopic minimally invasive cardiac surgery (MICS) approach without cardiopulmonary bypass.

CASE PRESENTATION: A 57-year-old woman presented with chest discomfort one day after falling and striking her left chest. Chest computed tomography revealed a fractured sewing needle, with one fragment embedded in the left ventricular myocardium and the other in the subcutaneous tissue. The patient remained hemodynamically stable, and removal was performed using a totally endoscopic MICS approach was performed. The intracardiac fragment was removed endoscopically without bleeding. The subcutaneous portion was extracted via a small skin incision. The postoperative course was uneventful, and the patient was discharged on day 5.

CONCLUSION

Totally endoscopic MICS without cardiopulmonary bypass may be a safe and effective option for removing intracardiac foreign bodies in carefully selected patients.

Для цитирования: Watabe Yoshinobu, Watanabe Shun, Suzuki Masato, Ito Toshiro. Totally endoscopic removal of a sewing needle penetrating the left ventricle without cardiopulmonary bypass.. Journal of cardiothoracic surgery. 2026. DOI: 10.1186/s13019-026-03939-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.