m+Medelevator.RU
← Поиск публикаций
BJOG : an international journal of obstetrics and gynaecology · 2006

Maternal total vascular resistance and concentric geometry: a key to identify uncomplicated gestational hypertension.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Valensise H, Vasapollo B, Novelli G P, Pasqualetti P, Galante A, Arduini D

Аннотация

OBJECTIVE: To evaluate the prognostic impact of elevated total vascular resistance (TVR) on the outcome of pregnancy in early mild gestational hypertension (EMGH).

DESIGN: Prospective observational study.

SETTING: Data collected from women with EMGH referred to the obstetrics outpatient clinic of Tor Vergata University from June 2003 to June 2005.

POPULATION: A total of 268 women with EMGH (systolic and diastolic blood pressure [BP] 140-150 mmHg and 90-99 mmHg, respectively, without significant proteinuria).

METHODS: Women had a maternal echocardiographic examination and BP examination within 24 hours of diagnosis. From this, the TVR was calculated and the geometric pattern of the left ventricle assessed.

MAIN OUTCOME MEASURES: Fetal/maternal adverse outcomes (pre-eclampsia, preterm delivery, placental abruption, other maternal medical problems, fetal distress, neonatal low birthweight, admittance to neonatal intensive care unit and perinatal death).

RESULTS: Ninety-two out of the 268 pregnancies showed adverse outcomes (34.3%). The best independent predictor for the composite of maternal and fetal complications was TVR (OR 64.4, 95% CI 25.9-160.1). The cutoff value was 1340 dyn seconds/cm(5) with a sensitivity and a specificity of 90 and 91%, respectively. Concentric geometry of the left ventricle was also an independent predictor (OR 4.72, 95% CI 1.85-12.04).

CONCLUSIONS: Echocardiography could help in identifying women with EMGH who subsequently develop maternal and fetal complications, allowing a classification in high-risk (TVR > 1340 dyn seconds/cm(5), concentric geometry of the left ventricle) and low-risk women (TVR < 1340 dyn seconds/cm(5), nonconcentric geometry of the left ventricle) for adverse outcomes of pregnancy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты