Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2013

Duration and magnitude of blood pressure below cerebral autoregulation threshold during cardiopulmonary bypass is associated with major morbidity and operative mortality.

Ono Masahiro, Brady Kenneth, Easley R Blaine, Brown Charles, Kraut Michael, Gottesman Rebecca F, Hogue Charles W

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVES

Optimizing blood pressure using near-infrared spectroscopy monitoring has been suggested to ensure organ perfusion during cardiac surgery. Near-infrared spectroscopy is a reliable surrogate for cerebral blood flow in clinical cerebral autoregulation monitoring and might provide an earlier warning of malperfusion than indicators of cerebral ischemia. We hypothesized that blood pressure below the limits of cerebral autoregulation during cardiopulmonary bypass would be associated with major morbidity and operative mortality after cardiac surgery.

METHODS

Autoregulation was monitored during cardiopulmonary bypass in 450 patients undergoing coronary artery bypass grafting and/or valve surgery. A continuous, moving Pearson's correlation coefficient was calculated between the arterial pressure and low-frequency near-infrared spectroscopy signals and displayed continuously during surgery using a laptop computer. The area under the curve of the product of the duration and magnitude of blood pressure below the limits of autoregulation was compared between patients with and without major morbidity (eg, stroke, renal failure, mechanical lung ventilation >48 hours, inotrope use >24 hours, or intra-aortic balloon pump insertion) or operative mortality.

RESULTS

Of the 450 patients, 83 experienced major morbidity or operative mortality. The area under the curve of the product of the duration and magnitude of blood pressure below the limits of autoregulation was independently associated with major morbidity or operative mortality after cardiac surgery (odds ratio, 1.36; 95% confidence interval, 1.08-1.71; P = .008).

CONCLUSIONS

Blood pressure management during cardiopulmonary bypass using physiologic endpoints such as cerebral autoregulation monitoring might provide a method of optimizing organ perfusion and improving patient outcomes from cardiac surgery.

Для цитирования: Ono Masahiro, Brady Kenneth, Easley R Blaine, Brown Charles, Kraut Michael, Gottesman Rebecca F, Hogue Charles W. Duration and magnitude of blood pressure below cerebral autoregulation threshold during cardiopulmonary bypass is associated with major morbidity and operative mortality.. The Journal of thoracic and cardiovascular surgery. 2013. DOI: 10.1016/j.jtcvs.2013.07.069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.