MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina60050718

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2024

Mechanical Complications of Proximal Femur Fractures Treated with Intramedullary Nailing: A Retrospective Study.

Lopez-Hualda Alvaro, García-Cabrera Esperanza Marin, Lobato-Perez Marina, Martinez-Martin Javier, Rossettini Giacomo, Leigheb Massimiliano, Villafañe Jorge Hugo

СтатьяПеревод в очереди

Аннотация

Background and

Objectives

This retrospective cohort study analyzes mechanical complications in hip fracture surgery using the Trochanteric Fixation Nail-Advanced (TFNA) implant. It investigates the correlation of these complications with demographic, intraoperative, and radiological factors, aiming to identify associated risk factors and suggest improvements in clinical surveillance and treatment strategies. Materials and

Methods

We enrolled 253 patients diagnosed with pertrochanteric hip fractures treated between 2017 and 2021, with 126 meeting the criteria for a minimum 6-month follow-up. Data on demographics, American Anesthesia Association Classification (ASA), comorbidities, AO/OTA [AO (Arbeitsgemeinschaft für Osteosynthesefragen)/OTA (Orthopedic Trauma Association)] fracture classification, procedural details, and time to failure were collected. Radiographs were evaluated for reduction quality, the tip-apex distance (TAD), progressive varus deviation, and identification of mechanical complications. Statistical analysis was performed using SPSS software.

Results

The predominant AO/OTA fracture classification was 31A2 in 67 cases (52.7%). Reduction quality was deemed good or acceptable in 123 cases (97.6%). The mean time to failure was 4.5 months (range: 2.2-6). The average TAD was 18 mm (range: 1.2-36), with a mean progressive varus deviation of 2.44° (range: 1.30-4.14). A good or acceptable reduction quality was observed in 97.6% of cases. Mechanical complications occurred in 21.4% of patients, with significant associations found with the lateral cortex fracture, use of a TFNA implant with a 130° angle, open reduction, and absence of prior osteoporosis treatment.

Conclusions

The study provides insights into mechanical complications in proximal femur fractures treated with the TFNA nail, emphasizing the need for enhanced clinical and radiographic surveillance, especially in patients without osteoporosis treatment. Our findings support the necessity for further clinical studies comparing these outcomes with other implant designs and underscore the importance of personalized treatment strategies to reduce complication rates.

Для цитирования: Lopez-Hualda Alvaro, García-Cabrera Esperanza Marin, Lobato-Perez Marina, Martinez-Martin Javier, Rossettini Giacomo, Leigheb Massimiliano, Villafañe Jorge Hugo. Mechanical Complications of Proximal Femur Fractures Treated with Intramedullary Nailing: A Retrospective Study.. Medicina (Kaunas, Lithuania). 2024. DOI: 10.3390/medicina60050718.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.