Analytical chemistry · 2021

Development of a Portable Method for Serum Lithium Measurement Based on Low-Cost Miniaturized Ultrasonic Nebulization Coupled with Atmospheric-Pressure Air-Sustained Discharge.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dong Jun-Hang, Yang Chun, Ding Han-Qing, Xing Peng-Ju, Zhou Fei-Yang, Tian Huan, Liu Xing, Zheng Hong-Tao, Hu Sheng-Hong, Zhu Zhen-Li

Аннотация

An accurate, rapid but cheap, and portable method for monitoring of serum lithium (Li) is highly desirable for mental patients who take Li medicine for treatment. Conventional techniques are usually bulky, costly, and cannot provide on-site real-time measurements. Herein, a miniaturized, reliable, cost-effective, and portable optical emission method for rapid and sensitive determination of serum Li was developed based on a combination of miniaturized ultrasonic nebulization (MUN) and a low-power (≈22 W) atmospheric-pressure air-sustained discharge (APAD) excitation source. The proposed method eliminates the use of any compressed gas or pump and can achieve serum Li detection within 40 s with low sample consumption (less than 20 μL serum). Except for dilution with water, no extra treatment is needed for serum Li analysis by MUN-APAD-OES. In addition, it offers a significant advantage of good tolerance to the coexisting high concentration of Na, K, Ca, and Mg, which is in contrast with the obvious matrix effect encountered in conventional inductively coupled plasma optical emission spectrometry (ICP-OES). Different operating parameters affecting the performance of MUN-APAD-OES were evaluated. Under optimized conditions, the detection limit of Li (670.8 nm) was calculated to be 0.6 μg L-1 (6 μg L-1 in serum). Finally, the accuracy of the proposed method was validated by the analysis of two certified reference materials (Seronorm serum L-1 and L-2 RUO), six real human serum samples, and eight real animal serum samples. All of the results indicate that the low-cost and low-power MUN-APAD-OES provides a promising reliable method for on-site serum Li measurement and may also be extended to other elements.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты