Jun Zhang, Juntao Ge, Shuli Liu, Li Long

Аннотация

PURPOSE: The purpose of this study is to determine whether singleport laparoscopic repair (SLR) for incarcerated inguinal hernia in children is superior toconventional repair (CR) approaches.

METHOD: Between March 2013 and September 2013, 126 infants and children treatedwere retrospectively reviewed. All the patients were divided into three groups. Group A (48 patients) underwent trans-umbilical SLR, group B (36 patients) was subjected to trans-umbilical conventional two-port laparoscopic repair (TLR) while the conventional open surgery repair (COR) was performed in group C (42 patients). Data regarding the operating time, bleeding volume, post-operative hydrocele formation, testicular atrophy, cosmetic results, recurrence rate, and duration of hospital stay of the patients were collected.

RESULT: All the cases were completed successfully without conversion. The mean operative time for group A was 15 ± 3.9 min and 24 ± 7.2 min for unilateral hernia and bilateral hernia respectively, whereas for group B, it was 13 ± 6.7 min and 23 ± 9.2 min. The mean duration of surgery in group C was 35 ± 5.2 min for unilateral hernia. The recurrence rate was 0% in all the three groups. There were statistically significant differences in theoperating time, bleeding volume, post-operative hydrocele formation, cosmetic results and duration hospital stay between the three groups (P < 0.001). No statistically significant differences between SLR and TLR were observed except the more cosmetic result in SLR.

CONCLUSION: SLR is safe and effective, minimally invasive, and is a new technology worth promoting.