m+Medelevator.RU
← Поиск публикаций
Nanoscale advances · 2025

Hematite α-Fe2O3 nanorods and laser-induced graphene for sustainable chemiresistive sensing of 1-butanol at room temperature.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tamiru Mengistu Mintesinot, Murray Richard, Russo Alida, Larrigy Cathal, Iacopino Daniela, Fitzpatrick Colin, Nolan Michael, Quinn Aidan J

Аннотация

Volatile organic compounds (VOCs) present in workplace and domestic settings present risks to human health, e.g., 1-butanol concentrations >100 ppm can cause central nervous system depression and respiratory/skin irritation. Traditional chemiresistive metal-oxide gas sensor platforms frequently rely on noble metal contact electrodes (Au,Pt) and high-temperature operation (200-600 °C), increasing cost and environmental footprint impacts. Consequently, there is an urgent need for sustainable and affordable materials for chemiresistive gas sensors that can operate at room temperature. Our approach combines hematite (α-Fe2O3) nanorods, synthesized via a low-impact co-precipitation method, with 3D porous laser-induced graphene (LIG) electrodes for room-temperature chemiresistive sensing of VOCs. Relative humidity (RH) plays a key role in charge transport through these LIG-contacted α-Fe2O3 nanorod assemblies, with baseline device resistance R 0 decreasing quasi-exponentially with increasing humidity. Device resistance increases upon exposure to 1-butanol, with resistance response ΔR/R 0 ∼ 185 ± 25% (n = 8) to 100 ppm 1-butanol at ∼55% RH, with 50-300 ppm linear range and limit of detection, LOD = 36 ± 11 ppm. Device response, ΔR/R 0, increases with increasing relative humidity from ∼20-60% RH, highlighting the key role of the hydrated α-Fe2O3 surfaces on the sensing mechanism. Measured response values represent a ∼10-fold improvement in sensitivity vs. reported room-temperature performance for devices based on α-Fe2O3 nanocubes. Further, the estimated cumulative energy demand (CED) for the α-Fe2O3 nanorod active nanomaterial is ∼1000 times lower than reported data for devices with comparable sensitivity, which employed α-Fe2O3 nanocubes and reduced graphene oxide hybrids. Estimated CED values for the 3-D porous LIG electrodes also show orders of magnitude reduction vs. values for conventional metal contact electrodes. Finally, we show that the response time constants of these LIG-contacted α-Fe2O3 nanorod devices can be used together with chemiresistive ΔR/R 0 response for effective discrimination of 1-butanol vs. other short-chain alcohols (methanol, ethanol, 2-propanol) and non-polar VOCs (acetone, toluene, hexane).

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты