MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6c01082

Медицинская библиотека · Analytical chemistry · 2026

Machine Learning-Enabled Multidimensional Ratiometric Sensor Array for Accurate Discrimination and Quantification of Tetracyclines.

Zhao Xu, Yue Shuai, Qin Xue-Bing, Cheng Feng-Ting, Xi Si-Ping, Yu Meng-Xue, Yan Zhu-Ying, Chen Li-Jian, Yan Xiu-Ping

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Extensive use of tetracycline antibiotics (TCs) threatens ecosystems and human health, necessitating sensitive and selective analytical monitoring approaches. Herein, we report an amino-functionalized mesoporous-silica-confined nanosensor (PLNP@SiO2-NH2) that enables self-referenced ratiometric detection and pattern recognition-based discrimination and quantification of TCs. Aminated mesoporous silica effectively enriches and rigidly immobilizes TCs, triggering the turn-on of the intrinsic green fluorescence signal (IG) of TCs. Meanwhile, the strong UV absorption of TCs at 254 nm induces an inner-filter effect, attenuating the effective excitation of the nanoprobe and leading to the decay of the 700 nm near-infrared emission reference signal (I700). These directional response signals exhibit remarkable intrinsic anti-interference capability and signal amplification. Leveraging the multichannel IG/I700 ratiometric fingerprints under single-wavelength excitation, combined with linear discriminant analysis (LDA) and hierarchical cluster analysis (HCA), the sensor effectively discriminates tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC), and doxycycline (DOX) across wide concentration gradients in both single-component and binary mixture systems, with discrimination sensitivity surpassing that of existing sensor arrays. The detection limits for the four TCs are 0.136 μM (OTC), 0.021 μM (DOX), 0.039 μM (TC), and 0.247 μM (CTC). The sensor demonstrates excellent antimatrix interference capability (matrix effect values from 0.92 to 1.04) and quantitative accuracy in milk samples (recoveries ranging from 95.40% ± 1.68% to 109.40% ± 1.12%). The sensor array also exhibits outstanding TCs discrimination capability in milk samples, confirming its robustness and reliability for high-throughput screening in complex food matrices.

Для цитирования: Zhao Xu, Yue Shuai, Qin Xue-Bing, Cheng Feng-Ting, Xi Si-Ping, Yu Meng-Xue, Yan Zhu-Ying, Chen Li-Jian, Yan Xiu-Ping. Machine Learning-Enabled Multidimensional Ratiometric Sensor Array for Accurate Discrimination and Quantification of Tetracyclines.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c01082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.