BACKGROUND

Minimally invasive Q3 repair has been proposed for acute Achilles tendon rupture with low rate of complications. However there are still controversies about optimal technique. In this study we aimed to describe Endobutton-assisted modified Bunnell configuration as a new Achilles tendon repair technique and evaluate its biomechanical properties comparing with native tendon and Krackow technique.

METHODS

27 ovine Achilles tendons were obtained and randomly placed into 3 groups with 9 specimens ineach. The Achilles tendons were repaired with Endobutton-assisted modified Bunnell technique in group 1, Krackow suture technique in group 2 and group 3 was defined as the control group including native tendons. Unidirectional tensile loading to failure was performed at 25mm/min. Biomechanicalproperties such as peak force to failure (N), stress at peak (MPa), elongation at failure, and Young'smodulus (GPa) was measured for each group. All groups were compared with each other using one-wayANOVA followed by the Tukey HSD multiple comparison test (a=0.05).

RESULTS

The average peak force (N) to failure of group 1 and group 2 and control group was 415.6±57.6, 268.1±65.2 and 704.5±85.8, respectively. There was no statistically significant difference between native tendon and group 1 for the amount elongation at failure (p>0.05).

CONCLUSIONS

Regarding the results, we concluded that Endobutton-assisted modified Bunnell technique provides stronger fixation than conventional techniques. It may allow early range of motion and can be easily applied in minimally invasive and percutaneous methods particularly for cases with poor quality tendon at the distal part of rupture.

LEVEL OF EVIDENCE: Level II, Biomechanical research study.

Для цитирования: Huri Gazi, Biçer Ömer Sunkar, Ozgözen Levent, Uçar Yurdanur, Garbis Nickolas G, Hyun Yoon Suk. A novel repair method for the treatment of acute Achilles tendon rupture with minimally invasive approach using button implant: a biomechanical study.. Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 2013. DOI: 10.1016/j.fas.2013.06.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.