MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sleep.2025.106542

Медицинская библиотека · Sleep medicine · 2025

The impact of acetazolamide and dronabinol on the physiological endotypes responsible for obstructive sleep apnea.

Thomson Luke D J, Landry Shane A, Maddison Kathleen, Walsh Rosemarie, Bleackley Mark R, Hamilton Garun S, Joosten Simon A, Walsh Jennifer, Edwards Bradley A

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVES

To investigate the effect of differing doses of the combination of acetazolamide and dronabinol (Aceta-Dro) on the obstructive sleep apnea (OSA) endotypes and their relationship to OSA severity.

METHODS

We retrospectively analysed data from a double-blind, randomized, placebo-controlled trial of 3 different doses of Aceta-Dro [Low(125mg/2.5 mg), Medium(250mg/5 mg), High(500mg/10 mg)] in OSA patients. OSA endotypes (collapsibility [VPASSIVE], Loop gain [LG], Arousal threshold [ArTH], and muscle compensation [VCOMP]) were extracted from polysomnography signals using validated algorithms. Linear mixed models were employed to assess the impact of treatment condition on the endotypes. Linear regressions assessed the relationship between the changes in endotypes vs. apnea-hypopnea index (AHI) and to predict treatment response from baseline endotypes.

RESULTS

Relative to placebo, Aceta-Dro dose-dependently reduced LG by 11 % (p = 0.18), 18.5 % (p = 0.022) and 20.5 % (p = 0.016). The reduction in LG was associated with a decrease in AHI in only the high dose condition (R2 = 0.78, p = 0.004). Aceta-Dro improved VPASSIVE in the low dose condition (+13 %, p = 0.005) only, which was strongly associated with AHI reduction (R2 = 0.71, p = 0.005). Aceta-Dro had no impact on VCOMP or ArTH. A higher baseline LG predicted treatment response in the high dose (R2 = 0.56, p = 0.03), with a similar trend observed in the low dose group. More severe collapsibility (lower VPASSIVE) predicted treatment response to both low (R2 = 0.46, p = 0.07) and medium dose (R2 = 0.50, p = 0.03) conditions.

CONCLUSIONS

Mechanistically, our findings suggest that medium and high doses of Aceta-Dro primarily reduce OSA severity by lowering loop gain, while the efficacy of the low dose was due to improved airway collapsibility.

Для цитирования: Thomson Luke D J, Landry Shane A, Maddison Kathleen, Walsh Rosemarie, Bleackley Mark R, Hamilton Garun S, Joosten Simon A, Walsh Jennifer, Edwards Bradley A. The impact of acetazolamide and dronabinol on the physiological endotypes responsible for obstructive sleep apnea.. Sleep medicine. 2025. DOI: 10.1016/j.sleep.2025.106542.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.