Bacteria in Extracorporeal Membrane Oxygenation Circuit Clots of a Patient With Persistent Bacteremia: A Case Report.

Drop Joppe G, Verhage Latisha, van Westreenen Mireille, Wildschut Enno D, de Hoog Matthijs, van Beusekom Heleen, van Ommen C Heleen

Клинический случайСтатьяПеревод в очереди

Аннотация

A neonate with pulmonary hypertension was supported with extracorporeal membrane oxygenation (ECMO). During ECMO support, the patient developed Enterococcus faecalis bacteremia, treated with targeted antibiotics. Despite the maximum dose of antibiotics, routine blood cultures remained positive throughout the ECMO treatment. A circuit change was performed due to buildup of thrombotic material and disseminated intravascular coagulation (DIC) inside the circuit. Thrombus formation was more extensive in the first than the second circuit. Gram-positive diplococci were present in all initial circuit clots and gram-positive masses surrounded by fibrin were found inside thrombi of the second circuit. Scanning electron microscopy (SEM) revealed a dense fibrin network with embedded red blood cells and bacteria in the first circuit. In the second circuit, SEM analysis revealed scattered micro thrombi. Polymerase chain reaction for identification of bacteria in the thrombus of the first circuit showed the same bacteria as found in blood cultures and did not achieve a sufficient signal in the second circuit. This case report shows that bacteria can nestle in thrombi of an ECMO circuit and that there is a rationale for a circuit change in a patient with persistent positive blood cultures and DIC.

Для цитирования: Drop Joppe G, Verhage Latisha, van Westreenen Mireille, Wildschut Enno D, de Hoog Matthijs, van Beusekom Heleen, van Ommen C Heleen. Bacteria in Extracorporeal Membrane Oxygenation Circuit Clots of a Patient With Persistent Bacteremia: A Case Report.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2023. DOI: 10.1097/mat.0000000000001980.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.