MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.redare.2026.502196

Медицинская библиотека · Revista espanola de anestesiologia y reanimacion · 2026

Baskar® Mask versus ProSeal™ laryngeal mask airway for airway sealing and clinical performance in gynecologic laparoscopic surgery: A randomized trial.

Saad M G, Gaballa N K, Alkashgari H R, Abodonya A, Salah Elsawy A G, Abouelnasr Khalifa A M, Abdalla Moursi S, Mostafa Elshamy M, Hegab M, Ismail E F, Deyab A, Elsafty R, Eltanani I

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the oropharyngeal leak pressure and clinical performance of the Baska® mask and the ProSeal™ laryngeal mask airway (LMA) during controlled ventilation in gynecologic laparoscopic surgery.

METHODS

This prospective randomized controlled trial included 100 adult women with American Society of Anesthesiologists (ASA) physical status I-II undergoing elective gynecologic laparoscopic surgery. After induction of general anesthesia, patients were randomized to insertion of either the Baska mask (BM group, n = 50) or the ProSeal laryngeal mask airway (PL group, n = 50). The primary outcome was oropharyngeal leak pressure measured 10 min after establishment of pneumoperitoneum. Secondary outcomes included insertion time, ease of insertion, number of insertion attempts, intraoperative device displacement, and perioperative airway-related complications.

RESULTS

Oropharyngeal leak pressure was significantly higher in the BM group than in the PL group (median [IQR], 31 [28-33] vs 26 [25-28] cmH2O; p < 0.001). Insertion time was significantly shorter with the Baska mask (9 [7-10] s vs 15 [13-16.8] s; p < 0.001). First-attempt success rates were comparable (96% vs 90%). Device displacement, blood-tinged sputum, and postoperative pharyngolaryngeal discomfort were not significantly different between groups. No patient required endotracheal intubation, and no episodes of vomiting occurred.

CONCLUSION

In gynecologic laparoscopic surgery, the Baska mask provided higher oropharyngeal leak pressure and faster insertion than the ProSeal LMA, with a comparable perioperative safety profile.

Для цитирования: Saad M G, Gaballa N K, Alkashgari H R, Abodonya A, Salah Elsawy A G, Abouelnasr Khalifa A M, Abdalla Moursi S, Mostafa Elshamy M, Hegab M, Ismail E F, Deyab A, Elsafty R, Eltanani I. Baskar® Mask versus ProSeal™ laryngeal mask airway for airway sealing and clinical performance in gynecologic laparoscopic surgery: A randomized trial.. Revista espanola de anestesiologia y reanimacion. 2026. DOI: 10.1016/j.redare.2026.502196.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.