MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/uog.13438

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2014

Maternal aspects of fetal cardiac intervention.

Wohlmuth C, Tulzer G, Arzt W, Gitter R, Wertaschnigg D

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Fetal cardiac interventions have the potential to alter natural disease progression and reduce morbidity and mortality in children. Although there are already encouraging data on fetal outcome, information on maternal morbidity and mortality after intervention is scarce. The aim of the present study was to assess maternal aspects, pregnancy-associated risks and adverse events in 53 intrauterine cardiac interventions.

METHODS

Between October 2000 and December 2012, 53 fetal cardiac interventions were performed in 47 patients (43 aortic valve dilations in 39 patients, seven pulmonary valve dilations in six patients and three balloon atrioseptostomies in two patients). Median gestational age was 26 + 4 (range, 20 + 3 to 33 + 1) weeks. Interventions were performed by an ultrasound-guided percutaneous approach under general anesthesia. All medical records and patient charts were analyzed retrospectively.

RESULTS

All women were considered to be healthy in the preoperative assessment; 39 (83%) patients continued pregnancy until term and eight of 47 patients had an intrauterine fetal death (IUFD) and were induced. Postoperative nausea was reported in 29.8% of patients and abdominal pain in 36.2% of patients on the day of surgery. Preterm contractions were observed in two patients; no preterm prelabor rupture of membranes occurred. One severe postpartum hemorrhage was observed in a patient with IUFD and subsequent induction; however, this was unrelated to the balloon valvuloplasty. No intensive care unit admission and no major anesthesia-associated complications (aspiration, anaphylactic reaction, cardiovascular collapse, damage to teeth, laryngeal damage, awareness or hypoxic brain damage) were observed. Maternal mortality was zero. A significant learning curve was observed in terms of duration of intervention.

CONCLUSION

In our experience, percutaneous needle-guided fetal cardiac intervention seems to be a safe procedure for the mother. In 53 procedures no major maternal complication directly related to the intervention was observed.

Для цитирования: Wohlmuth C, Tulzer G, Arzt W, Gitter R, Wertaschnigg D. Maternal aspects of fetal cardiac intervention.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2014. DOI: 10.1002/uog.13438.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.