PURPOSE: To report the use of a fenestrated stent-graft to manage a traumatic rupture of the juxtahepatic inferior vena cava (IVC).

CASE REPORT: A 62-year-old man was involved in a traffic accident and hospitalized for severe right leg fractures. Computed tomography also uncovered liver contusion and retroperitoneal hematoma. The next day, he became hemodynamically unstable; a huge retroperitoneal hematoma had developed from a rupture of the juxtahepatic IVC. An emergent procedure to implant a self-expanding fenestrated stent-graft was successful in repairing the IVC injury and maintaining hepatic venous return. The patient recovered and continues in good health with a patent endograft 16 months after treatment.

CONCLUSIONS

This experience supports the efficacy of fenestrated endograft implantation for emergent repair of IVC injuries, although proper facilities, an experienced interventional team, and an assortment of devices must be available.

Для цитирования: Watarida Shoji, Nishi Takao, Furukawa Akira, Shiraishi Shoichiro, Kitano Haruhisa, Matsubayashi Keiji, Imura Masato, Yamazaki Michio. Fenestrated stent-graft for traumatic juxtahepatic inferior vena cava injury.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2002. DOI: 10.1177/152660280200900122.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.