MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/sc.2009.107

Медицинская библиотека · Spinal cord · 2009

Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI.

Craven B C, Morris A R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

Observational study.

OBJECTIVES

To report the intra-rater (one rater), inter-rater (two raters) and inter-session (one subject, sessions 1-5) reliability of lower extremity modified Ashworth scale (MAS) scores among patients with chronic spinal cord injury (SCI).

SETTING

Tertiary Academic Rehab Centre in Toronto, Canada.

METHODS

MAS scores of 20 subjects with chronic SCI (C5-T10 AIS A-D>12 months) were recorded for the hip abductors and adductors, knee flexors and extensors, and ankle plantar and dorsiflexors. MAS scores were assessed by two blinded raters (A and B) at the same time of day, weekly for 5 weeks using standardized test positions, a one-cycle per second metronome, with ratings recorded on the second cycle. MAS score reproducibility [intra-rater, inter-rater] were calculated using Cohen's Kappa. Intraclass correlation coefficients (ICCs) were calculated to determine inter-session (trials 1-5) reliability; Kappa values >or=0.81 and ICC values >or=0.75 were desired.

RESULTS

Intra-rater reliability was fair to almost perfect (0.2<kappa<1.0) and differed between raters. Inter-rater reliability was poor-to-moderate (kappa<0.6) for all muscle groups. Inter-session reliability for a single rater was fair-to-good (0.4<ICC<0.75) for all muscle groups.

CONCLUSIONS

MAS was not reliable as an intra-rater tool for all raters, and showed poor inter-rater and modest inter-session reliability. MAS has inadequate reliability for determining lower extremity spasticity between raters (inter-rater) or over time (inter-session). It is recommended that the rehabilitation science community seek alternative measures for quantifying spasticity.

Для цитирования: Craven B C, Morris A R. Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI.. Spinal cord. 2009. DOI: 10.1038/sc.2009.107.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.