BACKGROUND

Estimations of D-dimer correlate with deep vein thrombosis and pulmonary thromboembolism and may serve as a marker of cortical venous sinus thrombosis (CVST).

AIM: To study the usefulness of D-dimer in the diagnosis of CVST.

MATERIALS AND

METHODS

A total of 26 patients with CVST were subjected to a detailed medical history and neurological evaluation. A cranial MRI was carried out on a 1.5T scanner using T1, T2, and DWI sequences and two-dimensional time of flight MR venography. D-dimer was estimated using a rapid latex agglutination slide test using monoclonal antibodies.

RESULTS

The age of patients ranged between 16 and 70 years old (median 31 years old); 8 were males and were examined after a mean duration of 22 days of symptoms. Cortical venous thrombosis was attributed to puerperium in 4 patients, infection in 5 patients, and pregnancy, dehydration, insect bite, and migraine in 1 patient each. Superior sagittal sinus was involved in 15 patients, transverse sinus in 16 patients, straight sinus in 3 patients, sigmoid sinus in 7 patients, and cavernous and deep system in 1 patient each. A total of 12 patients had more than one sinus involvement. D-dimer was positive in 20 patients and correlated with the duration of symptoms but not with the extent of sinus thrombosis and the outcome.

CONCLUSION

D-dimer is useful in patients suspected of CVST and patients with positive test results should be urgently sent for MR imaging.

Для цитирования: Misra Usha K, Kalita Jayantee, Bansal Vikas. D-dimer is useful in the diagnosis of cortical venous sinus thrombosis.. Neurology India. 2009. DOI: 10.4103/0028-3886.48822.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.