DOI 10.1097/sla.0000000000006409

Медицинская библиотека · Annals of surgery · 2024

Early Detection of Ventilator-associated Pneumonia From Exhaled Breath in Intensive Care Unit Patients.

Bakali Umer, Killawala Chitvan, Monteagudo Evelise, Cobler-Lichter Michael D, Tito Luciana, Delamater Jessica, Shagabayeva Larisa, Collie Brianna L, Lyons Nicole B, Dikici Emre, Deo Sapna K, Daunert Sylvia, Schulman Carl I

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Evaluate associations between volatile organic compounds (VOCs) in heat and moisture exchange (HME) filters and the presence of ventilator-associated pneumonia (VAP).

BACKGROUND

Clinical diagnostic criteria for VAP have poor interobserver reliability, and cultures are slow to result. Exhaled breath contains VOCs related to gram-negative bacterial proliferation, the most identified organisms in VAP. We hypothesized that exhaled VOCs on HME filters can predict nascent VAP in mechanically ventilated intensive care unit patients.

METHODS

Gas chromatography-mass spectrometry was used to analyze 111 HME filters from 12 intubated patients who developed VAP. Identities and relative amounts of VOCs were associated with dates of clinical suspicion and culture confirmation of VAP. Matched pairs t tests were performed to compare VOC abundances in HME filters collected within 3 days pre and postclinical suspicion of VAP (pneumonia days), versus outside of these days (non-pneumonia days). A receiver operating characteristic curve was generated to determine the diagnostic potential of VOCs.

RESULTS

Carbon disulfide, associated with the proliferation of certain gram-negative bacteria, was found in samples collected during pneumonia days for 11 of 12 patients. Carbon disulfide levels were significantly greater ( P = 0.0163) for filters on pneumonia days. The Area Under the Curve of the Reciever Operating Characteristic curve (AUC ROC) for carbon disulfide was 0.649 (95% CI: 0.419-0.88).

CONCLUSIONS

Carbon disulfide associated with gram-negative VAP can be identified on HME filters up to 3 days before the initial clinical suspicion, and approximately a week before culture confirmation. This suggests VOC sensors may have potential as an adjunctive method for early detection of VAP.

Для цитирования: Bakali Umer, Killawala Chitvan, Monteagudo Evelise, Cobler-Lichter Michael D, Tito Luciana, Delamater Jessica, Shagabayeva Larisa, Collie Brianna L, Lyons Nicole B, Dikici Emre, Deo Sapna K, Daunert Sylvia, Schulman Carl I. Early Detection of Ventilator-associated Pneumonia From Exhaled Breath in Intensive Care Unit Patients.. Annals of surgery. 2024. DOI: 10.1097/sla.0000000000006409.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.