m+Medelevator.RU
← Поиск публикаций
Clinical journal of the American Society of Nephrology : CJASN · 2010

Emergence of gentamicin-resistant bacteremia in hemodialysis patients receiving gentamicin lock catheter prophylaxis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Landry Daniel L, Braden Gregory L, Gobeille Stephen L, Haessler Sarah D, Vaidya Chirag K, Sweet Stephen J

Аннотация

BACKGROUND AND OBJECTIVES: Antibiotic locks in catheter-dependent chronic hemodialysis patients reduce the rate of catheter-related blood stream infections (CRIs), but there are no data regarding the long-term consequences of this practice.

DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Over a 4-year period, from October 1, 2002, to September 30, 2006, we initiated a gentamicin and heparin lock (GHL) protocol in 1410 chronic hemodialysis patients receiving dialysis through a tunneled catheter in eight outpatient units.

RESULTS: Within the first year of the GHL protocol, our CRI rate decreased from 17 to 0.83 events per 1000 catheter-days. Beginning 6 months after initiation of the GHL protocol, febrile episodes occurred in 13 patients with coagulase-negative Staphylococcus bacteremia resistant to gentamicin. Over the 4 years of GHL use, an additional 10 patients developed 11 episodes of gentamicin-resistant CRI (including 7 with Enterococcus faecalis), in which there were 4 deaths, 2 cases of septic shock requiring intensive care unit admission, and 4 cases of endocarditis. Because of these events, the GHL protocol was discontinued at the end of 2006.

CONCLUSIONS: Although the use of GHL effectively lowered the CRI rate in our dialysis population, gentamicin-resistant CRIs emerged within 6 months. Gentamicin-resistant infections are a serious complication of the long-term use of GHLs. Alternative nonantibiotic catheter locks may be preferable to decrease the incidence of CRIs without inducing resistant pathogens.