MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-77276-y

Медицинская библиотека · Scientific reports · 2024

Identification of peripheral nerve functional fascicles in Sprague-Dawley rats by the carbon quantum dot-Annexin V antibody complex.

Meng Xianyu, Li Changqing, Cui Aoyun, Zhang Xu, Zhao Lina, Zhao Binbin

СтатьяПеревод в очереди

Аннотация

To explore a method to identify the sensory and motor fascicles of the peripheral nerve to achieve accurate peripheral nerve functional fascicle suture. The peripheral nerve Sunderland V injury model, muscle branch of the femoral nerve and saphenous nerve were established in the bilateral femoral nerves of Sprague-Dawley (SD) rats. The specific samples were grouped as follows: the main trunk of the femoral nerve was exposed bilaterally and cut with microscopic scissors in the main trunk of the femoral nerve to prepare a model of Sunderland V injury in the mixed fascicle of peripheral nerves; the muscle branch of the femoral nerve was exposed bilaterally and cut in the middle section of the muscle branch of the femoral nerve to prepare a model of Sunderland V injury in the motor fascicle of peripheral nerves; the saphenous nerve was exposed bilaterally and cut at 1 cm below the patella to prepare a model of Sunderland V injury to the sensory fascicle of the peripheral nerves. A carbon quantum dot (CD)-annexin V antibody complex was prepared and applied to the distal and proximal nerve stumps of the peripheral nerve Sunderland V injury model groups of SD rats. Under the excitation light source of a 380 nm uv lamp, fluorescence color development was observed under a fluorescence microscope after 5, 10, 15, and 20 min. At 5 min, sections of the bilateral femoral nerve trunk, muscular branches of the femoral nerve, and Sunderland V lesion of the saphenous nerve in SD rats were only dark in color under the microscope, and there was no difference in fluorescence. The intensity of the staining increased significantly for 10-20 min. The sensory fascicles and saphenous nerves of the femoral nerve trunk showed blue fluorescence under the CD-Annexin V antibody complex staining, while the motor fascicles and muscle branches of the femoral nerve trunk showed no fluorescence. Fluorescence intensity gradually decreased after 20 min of staining. There was no significant difference in the staining intensity at 5, 10, 15, and 20 min in each group. Our results suggest that the CD-Annexin antibody complex can be used to identify functional fascicles of peripheral nerves in SD rats.

Для цитирования: Meng Xianyu, Li Changqing, Cui Aoyun, Zhang Xu, Zhao Lina, Zhao Binbin. Identification of peripheral nerve functional fascicles in Sprague-Dawley rats by the carbon quantum dot-Annexin V antibody complex.. Scientific reports. 2024. DOI: 10.1038/s41598-024-77276-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.