MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijid.2025.108349

Медицинская библиотека · International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases · 2025

Clinical application evaluation of droplet digital PCR based on multi-point monitoring in the real world for patients with suspected bloodstream infection in the ICU.

Cai Yingying, Yang Yue, Zhang Ying, Yu Sufei, Shi Qingxin, Li Jun, Xu Jiaqin, Zhu Hongguo, Chen Mengyuan, Shen Bo

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Bloodstream infections are associated with high morbidity and mortality in patients in the intensive care unit (ICU), necessitating rapid pathogen identification. This study evaluates the diagnostic performance and clinical utility of droplet digital PCR (ddPCR) in patients in the ICU with suspected bloodstream infection.

METHODS

This retrospective, single-centre study included 101 adults with suspected bloodstream infection in the ICU. 303 ddPCR samples were collected at three time points after ICU admission: 0-1 (T1), 3-4 (T2), and 6-8 days (T3). ddPCR was compared with blood culture collected at T1 for detection performance, and compared the distributions, copy numbers, and clinical concordance of pathogens across three time points.

RESULTS

ddPCR had a 78.2% detection rate versus 32.7% for blood culture and showed 86.0% sensitivity, and 63.6% specificity. Accuracy decreased with delayed sampling (T1: 57.4%, T2: 52.5%, T3: 40.6%). Clinical concordance was >80% for Klebsiella pneumoniae, Escherichia coli, and Staphylococcus aureus; >50% for Pseudomonas aeruginosa and Acinetobacter baumannii; but <40% for Enterococcus and Streptococcus spp. A cut-off of 1 copy/µL for S. aureus, 2 copies/µL for K. pneumoniae, P. aeruginosa, and 5 copies/µL for E. coli, A. baumannii, improved bloodstream infection diagnosis. The detection of multiple pathogens was highest across three time points (T1: 28.7%, T2: 17.8%, T3: 19.8%). 10 in 22 patients with persistently negative tests confirmed to be true negatives. The copy numbers of 28 cases with persistently same pathogen tested correlated dynamically with procalcitonin and C-reactive protein levels.

CONCLUSION

ddPCR improves an etiological diagnosis in bloodstream infection, enabling rapid quantification, dynamic monitoring, and better antibiotic stewardship.

Для цитирования: Cai Yingying, Yang Yue, Zhang Ying, Yu Sufei, Shi Qingxin, Li Jun, Xu Jiaqin, Zhu Hongguo, Chen Mengyuan, Shen Bo. Clinical application evaluation of droplet digital PCR based on multi-point monitoring in the real world for patients with suspected bloodstream infection in the ICU.. International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases. 2025. DOI: 10.1016/j.ijid.2025.108349.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.