DOI 10.1016/j.jshs.2019.12.001
Estimates of voluntary activation in individuals with anterior cruciate ligament reconstruction: Effects of type of stimulator, number of stimuli, and quantification technique.
Аннотация
BACKGROUND
Accurate quantification of voluntary activation is important for understanding the extent of quadriceps dysfunction in individuals with anterior cruciate ligament reconstruction (ACLR). Voluntary activation has been quantified using both percent activation derived from the interpolated twitch technique and central activation ratio (CAR) derived from the burst superimposition technique, as well as by using different types of electrical stimulators and pulse train conditions. However, it is unclear how these parameters affect voluntary activation estimates in individuals with ACLR. This study was performed to fill this important knowledge gap in the anterior cruciate ligament literature.
METHODS
Quadriceps strength and voluntary activation were examined in 18 ACLR participants (12 quadriceps/patellar tendon graft, 6 hamstring tendon graft; time since ACLR: 1.06 ± 0.82 years, mean ± SD) at 90° of knee flexion using 2 stimulators (Digitimer and Grass) and pulse train conditions (3-pulse and 10-pulse). Voluntary activation was quantified by calculating both CAR and percent activation.
RESULTS
Results indicated that voluntary activation was significantly overestimated by CAR when compared with percent activation (p < 0.001). Voluntary activation estimates were not affected by pulse train conditions when using percent activation; however, 3-pulse stimuli resulted in greater overestimation than 10-pulse stimuli when using CAR (p = 0.003). Voluntary activation did not differ between stimulators (p > 0.05); however, the Digitimer evoked greater torque at rest than the Grass (p < 0.001).
CONCLUSION
These results indicate that percent activation derived from the interpolated twitch technique provides superior estimates of voluntary activation than CAR derived from burst superimposition and is less affected by pulse train conditions or stimulators in individuals with ACLR.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.