MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiochem.2019.04.009

Медицинская библиотека · Clinical biochemistry · 2019

Commonly used fluoroquinolones cross-react with urine drug screens for opiates, buprenorphine, and amphetamines.

Colby Jennifer M, Patel Pratish C, Fu Darwin Y, Rutherford Nicola J

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Fluoroquinolone antibiotics are commonly used in the treatment of infections and have previously been confirmed to cross-react with previous generations of opiates immunoassays. In this work we evaluated the cross-reactivity of the three fluoroquinolones in use at our institution with a panel of 10 urine drug screens.

DESIGN AND

METHODS

Drug preparations of levofloxacin, ciprofloxacin, and moxifloxacin that were designed for intravenous delivery were added to drug-free urine at varying concentrations. Spiked urine samples were screened for illicit and therapeutic drugs on an Abbott Architect c16000 automated chemistry analyzer. Percent cross-reactivity was calculated.

RESULTS

Levofloxacin displayed clinically relevant cross-reactivity with the Abbott MULTIGENT opiates and Thermo CEDIA® buprenorphine immunoassays but did not cross-react with the Abbott MULTIGENT oxycodone or methadone immunoassays. Moxifloxacin displayed clinically relevant cross-reactivity only with the Abbott MULTIGENT amphetamine/methamphetamine assay. Ciprofloxacin did not cross-react with any of the 10 immunoassays.

CONCLUSIONS

This study demonstrates that levofloxacin cross-reacts with modern immunoassays for two related opioids (buprenorphine and morphine) and moxifloxacin cross-reacts with the amphetamine/methamphetamine assay. Urine concentrations of these fluoroquinolones that are consistent with therapeutic use produced results above commonly used-cutoffs for positivity. This underscores the necessity of confirmatory testing of presumptively positive urine drug screens.

Для цитирования: Colby Jennifer M, Patel Pratish C, Fu Darwin Y, Rutherford Nicola J. Commonly used fluoroquinolones cross-react with urine drug screens for opiates, buprenorphine, and amphetamines.. Clinical biochemistry. 2019. DOI: 10.1016/j.clinbiochem.2019.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.