MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15691861241241775

Медицинская библиотека · Hong Kong journal of occupational therapy : HKJOT · 2024

Smartwatch-based functional assessment for upper extremity impairment after musculoskeletal injuries: A pilot study.

Nam Hyung Seok, Han Sol, Leigh Ja-Ho, Bang Moon Suk

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Wearable sensors are increasingly applied to rehabilitation for arm movement analysis. However, simple and clinically relevant applications are scarce.

OBJECTIVES

To investigate the feasibility of single smart watch-based parameters for functional assessment in upper limb rehabilitation for musculoskeletal injuries using a commercial smart watch.

METHOD: Ten patients with unilateral shoulder pain and range-of-motion limitations were enrolled. They wore Galaxy Watch® and performed three sets of upper extremity tasks consisting of gross activities-of-daily-living tasks, Wolf Motor Function Test (WMFT), and Upper Extremity Functional Index (UEFI), and the acceleration and angular velocities were acquired. The motion segment size (MSS), representing motion smoothness from a clinical perspective, and various sensor-based parameters were extracted. The correlation between the parameters and clinical outcome measures were analyzed. The percent relative range (PRR) of the significant parameters was also calculated.

RESULTS

For overhead and behind body activity task set, mean MSS for elbow flexion/extension axis significantly correlated with WMFT score (R = 0.784, p = .012). For planar tasks, mean MSS for the forearm supination/pronation (R = 0.815, p = .007) and shoulder rotation (R = 0.870, p = .002) axes significantly correlated with WMFT score. For forearm and fine movement task set, mean MSS of the elbow flexion/extension angle showed significant correlation with WMFT (R = 0.880, p < .001) and UEFI (R = 0.718, p = .019). The total performance time (R = -0.741, p = .014) also showed significant correlation with WMFT score. The PRR for mean MSS in forearm supination (71.5%, planar tasks) and mean MSS in x-direction (49.8%, forearm and fine motor movements) were similar to the PRR of WMFT (58.5%), suggesting sufficient variation range across different degree of impairments.

CONCLUSION

The commercial smart watch-based parameters showed consistent potential for use in clinical functional assessments.

Для цитирования: Nam Hyung Seok, Han Sol, Leigh Ja-Ho, Bang Moon Suk. Smartwatch-based functional assessment for upper extremity impairment after musculoskeletal injuries: A pilot study.. Hong Kong journal of occupational therapy : HKJOT. 2024. DOI: 10.1177/15691861241241775.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.