Аннотация

PURPOSE: To evaluate the association between computed tomographic (CT) assessment of inferior alveolar nerve (IAN) canal cortical integrity and intraoperative IAN exposure.

MATERIALS AND

METHODS

This was a retrospective cohort study. The study sample included patients considered at high risk for IAN injury based on panoramic findings. The primary predictor variable was IAN canal integrity (intact or interrupted) assessed on coronal CT images. The secondary predictor variable was length of the cortical defect, in millimeters. The primary outcome variable was intraoperative visualization of the IAN. Other variables were demographic and operative parameters. Bivariate and multiple logistic regression analyses were used to evaluate the unadjusted and adjusted associations between the cortical integrity and IAN exposure. Diagnostic test characteristics were computed for cortical integrity and threshold cortical defect size. A P value < or = 0.05 was statistically significant.

RESULTS

The sample consisted of 51 subjects (57% female) with a mean age of 35.2 +/- 12.8 years. Of the 80 third molars available for evaluation, 52 third molars (64.1%) had evidence of loss of cortical integrity. The mean cortical defect length was 2.9 +/- 2.6 mm. Loss of cortical integrity had a high sensitivity (> or = 0.88) but low specificity (< or = 0.49) as a diagnostic test for IAN visualization. A cortical defect size > or = 3 mm was associated with an increased risk for intraoperative IAN visualization with a high sensitivity and specificity (> or = 0.82).

CONCLUSION

Cortical defect size on a maxillofacial CT has a high sensitivity and specificity for predicting intraoperative IAN exposure during third molar removal.

Для цитирования: Susarla Srinivas M, Sidhu Harlyn K, Avery Laura L, Dodson Thomas B. Does computed tomographic assessment of inferior alveolar canal cortical integrity predict nerve exposure during third molar surgery?. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2010. DOI: 10.1016/j.joms.2010.01.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.