MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bja.2026.04.056

Медицинская библиотека · British journal of anaesthesia · 2026

Impact of high versus low fraction of inspired oxygen for anaesthetic washout and extubation on postoperative pulmonary atelectasis formation and oxygenation: a randomised controlled trial.

Paschold Béla-Simon, Braeuer Ben L P, Santer Peter, Wichelhaus Lisa-Marie, Alcala Glasiele, Robitaille Mark J, Woloszynek Stephen, Pinciroli Riccardo, Sahli Sebastian, Wachtendorf Luca J, Karimitar Arian, Goodspeed Valerie, Pensier Joris, Jungwirth Bettina, Baedorf-Kassis Elias, Amato Marcelo B P, Talmor Daniel, Schaefer Maximilian S

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Clinicians often administer 100% inspired oxygen (fraction of inspired oxygen [Fio2] = 1) for washout of volatile anaesthetics before tracheal extubation, potentially aggravating atelectasis formation and compromising oxygenation. We evaluated whether lower Fio2 during emergence from anaesthesia reduces atelectasis and improves oxygenation.

METHODS

We conducted a single-centre, randomised controlled trial (NCT06538740) in 48 adult participants undergoing elective surgery under general anaesthesia. Participants were randomised to receive either pure oxygen (100%) or lower (70% or 40%) Fio2 for anaesthetic washout before extubation. The primary outcome was atelectasis, assessed as changes in centre of ventilation and end-expiratory lung volume using electrical impedance tomography.

RESULTS

Twenty-four participants (mean age 57 [range: 19-82] yr; 42% female) were randomly allocated to receive pure oxygen and 24 received 40% or 70% Fio2. Participants receiving pure oxygen had a more ventral shift in the centre of ventilation (median [IQR], -0.3% [-2.2 to 1.3]), compared with lower Fio2 (1.3% [0.0-2.8]; P=0.041). Participants receiving pure oxygen also had a greater reduction in end-expiratory lung volume after extubation (-1067 [-1839 to -589] ml) compared with participants receiving lower Fio2 (-423 ml [-873 to -53]; P=0.006). There was no difference in end-expiratory lung volume between patients receiving 70% or 40% Fio2 (P=0.39). Spo2 (oxygen saturation measured by pulse oximetry) 10 min after extubation was higher in participants receiving 70% Fio2 (interaction P=0.028).

CONCLUSIONS

Avoiding pure oxygen before extubation preserved end-expiratory lung volume with more dorsal distribution of ventilation. Postextubation oxygenation was optimal with 70% Fio2.

Для цитирования: Paschold Béla-Simon, Braeuer Ben L P, Santer Peter, Wichelhaus Lisa-Marie, Alcala Glasiele, Robitaille Mark J, Woloszynek Stephen, Pinciroli Riccardo, Sahli Sebastian, Wachtendorf Luca J, Karimitar Arian, Goodspeed Valerie, Pensier Joris, Jungwirth Bettina, Baedorf-Kassis Elias, Amato Marcelo B P, Talmor Daniel, Schaefer Maximilian S. Impact of high versus low fraction of inspired oxygen for anaesthetic washout and extubation on postoperative pulmonary atelectasis formation and oxygenation: a randomised controlled trial.. British journal of anaesthesia. 2026. DOI: 10.1016/j.bja.2026.04.056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.