DOI 10.1097/cm9.0000000000001944
Intra-abdominal aortic balloon occlusion in the management of placenta percreta.
Аннотация
BACKGROUND
Massive bleeding is the main concern for the management of placenta percreta (PP). Intra-abdominal aortic balloon occlusion (IABO) is one method for pelvic devascularization, but the efficacy of IABO is uncertain. This study aims to investigate the outcomes of IABO in PP patients.
METHODS
We retrospectively reviewed the clinical data of PP cases from six tertiary centers in China between January 2011 and December 2015. PP cases with/without the use of IABO were analyzed. Propensity score matching analysis was performed to reduce the effect of selection bias. Postpartum hemorrhage (PPH) and the rate of hysterectomy, as well as neonatal outcomes, were analyzed.
RESULTS
One hundred and thirty-two matched pairs of patients were included in the final analysis. Compared with the control group, maternal outcomes, including PPH (68.9% vs. 87.9%, χ2 = 13.984, P < 0.001), hysterectomy (8.3% vs. 65.2%, χ2 = 91.672, P < 0.001), and repeated surgery (1.5% vs. 12.1%, χ2 = 11.686, P = 0.001) were significantly reduced in the IABO group. For neonatal outcomes, Apgar scores at 1 minute (8.67 ± 1.79 vs. 8.53 ± 1.68, t = -0.638, P = 0.947) and 5 minutes (9.43 ± 1.55 vs. 9.53 ± 1.26, t = 0.566, P = 0.293) were not significantly different between the two groups.
CONCLUSIONS
IABO can significantly reduce blood loss, hysterectomies, and repeated surgeries. This procedure has not shown harmful effects on neonatal outcomes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.