MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vec.12937

Медицинская библиотека · Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001) · 2020

Acute hemolytic reaction due to A-B mismatched transfusion in a cat with transient AB blood type.

Koenig Amie, Maglaras Christina H, Giger Urs

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To document a case of transient AB blood type indicated by immunochromatography in a type B cat following administration of an incompatible type A transfusion.

CASE SUMMARY: A 7-month-old neutered male domestic longhair cat was evaluted for anemia, pigmenturia, and intravascular hemolysis 1 day after receiving a feline whole blood transfusion. Neither blood donor nor patient had been blood-typed or crossmatched. The cat presented in shock with a severe non-regenerative anemia, hyperlactatemia, hyperbilirubinemia, hemoglobinemia, hemoglobinuria, and a positive saline slide agglutination test. Immunochromatographic blood typing tests initially indicated the cat had type AB blood, but crossmatch tests with blood from type A and type B donors suggested that the cat was type B. The cat was transfused with type B packed red blood cells without apparent complications and clinically improved. The cat's blood type reverted to type B once all the previously transfused type A cells were cleared from circulation. Furthermore, the original donor was subsequently identified as a Siamese cat and confirmed to have type A blood. While the cause of the original anemia remained unknown, the cat completely recovered and regained a normal hematocrit.

NEW OR UNIQUE INFORMATION PROVIDED: This is the first documented report of transient AB blood type diagnosed using immunochromatography after a transfusion mismatch and shows the utility of crossmatching or back-typing to identify the cat's correct blood type during the hemolytic transfusion reaction.

Для цитирования: Koenig Amie, Maglaras Christina H, Giger Urs. Acute hemolytic reaction due to A-B mismatched transfusion in a cat with transient AB blood type.. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2020. DOI: 10.1111/vec.12937.