DOI 10.1002/joa3.70442

Медицинская библиотека · Journal of arrhythmia · 2026

Safety and Efficacy of Two Venous Closure Devices Compared With Manual Compression After Atrial Fibrillation Ablation.

Shiomi Satoko, Tokutake Kenichi, Takato Ui, Sakurai Ryutaro, Yamazaki Yoshito, Matsumoto Takuya, Sato Hidenori, Oseto Hirotsuna, Yokoyama Masaaki, Yamashita Seigo, Yamane Teiichi, Tokuda Michifumi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

VASCADE MVP device has garnered attention as a novel femoral venous closure device. Manual compression (MC) is associated with prolonged bed rest and significant patient discomfort. Although Perclose ProGride/ProStyle device reduces bed rest duration, it can result in severe puncture site complications. The adoption of VASCADE MVP is anticipated to reduce the incidence of puncture site complications and facilitate early patient mobilization.

METHODS

A total of 858 patients undergoing catheter ablation were included in this study (MC: n = 196; Perclose: n = 547; VASCADE: n = 115). Perclose device was introduced in January 2018, and VASCADE device in September 2024. Venous closure devices were employed for all suitable femoral puncture sheaths. In the MC group, compression was released after 7 h or the following morning; in the Perclose group after 4 h and in the VASCADE group after three or 4 h. Total post-procedure time and vascular complications were compared among the groups.

RESULTS

The total post-procedure time was significantly shorter with VASCADE compared to Perclose and MC (22.6 ± 8.9 min vs. 29.6 ± 8.2 min and 30.4 ± 9.3 min, p < 0.001). The incidence of re-bleeding was comparable between Perclose and VASCADE (11% vs. 13%, p = 0.787). No serious complications were observed in VASCADE group, whereas three patients (1%) in Perclose group experienced major complications.

CONCLUSION

The use of VASCADE devices safely reduced both total post-procedure time and bedrest times for complete hemostasis, without an associated increase in complications.

Для цитирования: Shiomi Satoko, Tokutake Kenichi, Takato Ui, Sakurai Ryutaro, Yamazaki Yoshito, Matsumoto Takuya, Sato Hidenori, Oseto Hirotsuna, Yokoyama Masaaki, Yamashita Seigo, Yamane Teiichi, Tokuda Michifumi. Safety and Efficacy of Two Venous Closure Devices Compared With Manual Compression After Atrial Fibrillation Ablation.. Journal of arrhythmia. 2026. DOI: 10.1002/joa3.70442.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.