DOI 10.3760/cma.j.cn121094-20201217-00697
[Rapid determination of 30 volatile organic compounds in workplace air by gas chromatography].
Аннотация
Objective
To establish a method for rapid detection of DB-WAX capillary column and determination of the workplace air in 30 kinds of volatile organic pollutants.
Methods
In August 2020, N-pentane, n-hexane, methylcyclohexane, octane, Acetone, ethyl acetate, butanone, benzene, 3-pentanone, trichloroethylene, tetrachloroethylene, toluene, butyl acetate, 2-hexanone, Isoamyl acetate, ethylbenzene, p-xylene, m-xylene, amyl acetate, o-xylene, chlorobenzene, styrene, cyclohexanone, P-chlorotoluene, bromobenzene, M-dichlorobenzene, p-dichlorobenzene, O-dichlorobenzene, o-Chlorotoluene, 1, 2 , 4-trichlorobenzene of 30 kinds of substances in air were collected by activated carbon tube. After analysis by carbon disulfide, the analytical solution was analyzed by DB-WAX column and determined by FID detector.
Results
The above 30 kinds of volatile organic pollutants had good separation effect, the correlation coefficient of the standard curve was above 0.999, the relative standard deviation was 0.1%-3.2%, the desorption efficiency was 77.0%-117.1% , the lower limit of quantitation was 0.33-5.33 μg/ml, and the lowest quantitation concentration was 0.22-3.55 mg/m(3), the recoveries ranged was 95.4%-104.9%.
Conclusion
The method can effectively separate and accurately determine 30 volatile organic compounds in these workplaces, and the method is simple and quick.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.