MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.1c03392

Медицинская библиотека · Analytical chemistry · 2021

Development of a Standardized Microflow LC Gradient to Enable Sensitive and Long-Term Detection of Synthetic Anabolic-Androgenic Steroids for High-Throughput Doping Controls.

Delcourt Vivian, Garcia Patrice, Pottier Isabelle, Mansoibou Nasrine, Bache Nicolai, Glavieux Yohan, Chabot Benjamin, Perot Isabelle, André François, Loup Benoit, Barnabé Agnès, Popot Marie-Agnès, Bailly-Chouriberry Ludovic

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Synthetic androgenic anabolic steroids (AAS) are banned compounds and considered as major threats by both racing and sports international authorities. Hence, doping control laboratories are continually looking into analytical improvements to increase their detection capabilities, notably by means of emerging technologies. To enhance analytical performances for the detection of synthetic AAS such as stanozolol, specific chromatographic procedures have been developed using recent quaternary liquid chromatography technology originally designed for high-throughput standardized proteomics connected to mass spectrometry. Applying the newly designed elution procedures described in this paper to the analyses of stanozolol and its metabolites in complex matrixes revealed improved sensitivity compared to previously described high-throughput methods. Indeed, we report the consistent and reliable detection of 16β-hydroxy-stanozolol down to 10 pg/mL in equine urine and being detectable up-to 3 months after a microdosing administration. Furthermore, a five months long elimination of stanozolol and its metabolites could be monitored on horse mane sections after a single dose administration. Our work highlights novel solutions to detect AAS with improved sensitivity. The application of such developments constitutes new landmarks for doping control laboratories and could be extended to other targeted compounds in residue analysis, toxicology, and metabolomics. Based on this work, the developed chromatographic method is now freely available within the Evosep Plus program.

Для цитирования: Delcourt Vivian, Garcia Patrice, Pottier Isabelle, Mansoibou Nasrine, Bache Nicolai, Glavieux Yohan, Chabot Benjamin, Perot Isabelle, André François, Loup Benoit, Barnabé Agnès, Popot Marie-Agnès, Bailly-Chouriberry Ludovic. Development of a Standardized Microflow LC Gradient to Enable Sensitive and Long-Term Detection of Synthetic Anabolic-Androgenic Steroids for High-Throughput Doping Controls.. Analytical chemistry. 2021. DOI: 10.1021/acs.analchem.1c03392.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.