MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezag165

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2026

Impact of Partial- to Full-Support Escalation With Microaxial Flow Pumps Prior to Durable Left Ventricular Assist Device Implantation.

Lewin Daniel, Nersesian Gaik, Rojas Sebastian V, Pieri Marina, Szymanski Mariusz K, Koij Janajade, Netuka Ivan, Färber Gloria, Krasivski Ihor, Akhyari Payam, Saeed Diyar, Loforte Antonio, Pitts Leonard, Billion Michael, Moller Christian H, Schmack Bastian, Meyer Anna L, Haneya Assad, Schoenrath Felix, Ott Sascha, Scandroglio Mara, Lanmueller Pia, Bernhardt Alexander, Potapov Evgenij

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Microaxial flow pumps (mAFP) effectively bridge patients with cardiogenic shock to durable left ventricular assist device (dLVAD) implantation. The partial-support mAFPs provide only up to 3.5 L/min, which might be insufficient for an effective circulatory support and preconditioning for a dLVAD implantation. Alternatively, patients with refractory shock on partial support may benefit from an escalation to a full-support mAFP.

METHODS

A retrospective analysis of 130 patients was performed across 17 European cardiac centres who underwent dLVAD implantation following mAFP with or without venoarterial extracorporeal life support (VA-ECLS) between February 2015 and August 2022. Ninety-two patients (70.8%) were bridged on partial-support mAFP, while 38 patients (29.2%) underwent an escalation to full-support mAFP.

RESULTS

Median support duration was significantly longer in the escalation group (7 days [4, 11] vs 12 days [9, 21], P < .001). Patients in the escalation group were more likely to be weaned from VA-ECLS before dLVAD implantation, 10 (71.4%) vs 6 (11.3%), P < .001. Thirty-day survival was similar between the escalation and no-escalation groups, 89.5% vs 84.8% (IPTW-weighted OR, 1.00 [95% CI, 0.46-2.22], P = .992). Estimated 1-year survival was higher in the escalation group: 84.0% [95% CI, 73.0-96.6] vs 63.7% [95% CI, 54.3-74.6], HR 0.41 [95% CI, 0.17-0.99], P = .048. Patients with a combination of partial-support mAFP and VA-ECLS had a higher mortality risk than all other patients, HR 2.06 [95% CI, 1.16-3.36], P = .013.

CONCLUSIONS

In patients with partial-support mAFP and concomitant VA-ECLS, an escalation to a full-support mAFP may translate to improved survival and should be considered to facilitate VA-ECLS weaning.

Для цитирования: Lewin Daniel, Nersesian Gaik, Rojas Sebastian V, Pieri Marina, Szymanski Mariusz K, Koij Janajade, Netuka Ivan, Färber Gloria, Krasivski Ihor, Akhyari Payam, Saeed Diyar, Loforte Antonio, Pitts Leonard, Billion Michael, Moller Christian H, Schmack Bastian, Meyer Anna L, Haneya Assad, Schoenrath Felix, Ott Sascha, Scandroglio Mara, Lanmueller Pia, Bernhardt Alexander, Potapov Evgenij. Impact of Partial- to Full-Support Escalation With Microaxial Flow Pumps Prior to Durable Left Ventricular Assist Device Implantation.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2026. DOI: 10.1093/ejcts/ezag165.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.