MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2025.04.062

Медицинская библиотека · Journal of the American College of Cardiology · 2025

Effect of Microaxial Flow Pump on Hemodynamics in STEMI-Related Cardiogenic Shock.

Møller Jacob Eifer, Beske Rasmus Paulin, Jensen Lisette Okkels, Eiskjær Hans, Mangner Norman, Polzin Amin, Schulze P Christian, Skurk Carsten, Nordbeck Peter, Schrage Benedikt, Panoulas Vasileios, Zimmer Sebastian, Schäfer Andreas, Werner Nikos, Holmvang Lene, Kjærgaard Jesper, Engstøm Thomas, Udesen Nanna Louise Junker, Schmidt Henrik, Junker Anders, Wachtell Kristian, Terkelsen Christian Juhl, Christensen Steffen, Linke Axel, Burkhoff Daniel, Hassager Christian, DanGer Shock Investigators

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The microaxial flow pump (mAFP) improves survival in selected patients with ST-segment elevation myocardial infarction-induced cardiogenic shock (STEMI-CS). Understanding the impact on cardiac output (CO), cardiac power output (CPO), and pulmonary artery pressure (PAP) provides insight into the potential unloading effect of the device, which is a reduction in total intrinsic mechanical work of the heart.

OBJECTIVE

This study sought to determine the effect of mAFP on hemodynamics in STEMI-CS.

METHODS

This substudy of the DanGer (Danish-German) shock trial randomized patients with STEMI-CS to mAFP or standard of care. Patients were monitored using a pulmonary artery catheter. Outcome measures were CO, CPO, and mean PAP during the first 48 hours.

RESULTS

Of 324 patients admitted to the cardiac intensive care unit (CICU), 223 patients (68%) had data on hemodynamic monitoring: 98 patients (63%) in the standard of care, and 125 (74%) patients in the mAFP group. The median first measured CO after CICU admission was 3.4 L/min (Q1-Q3: 2.6-4.4 L/min) in the control vs 3.7 L/min (Q1-Q3: 3.2-4.5 L/min) in the mAFP group; P = 0.13. After 6 hours, the CO increased in and was consistently higher in the mAFP group from 12 hours until 48 hours. The first measured mean PAP in the CICU had a median value of 31 mm Hg (Q1-Q3: 29-39 mm Hg) in the standard of care group compared with 27 mm Hg (Q1-Q3: 23-33 mm Hg) in the mAFP group (P < 0.001) and remained lower at all time points in the mAFP. Also, the first measured PCWP was lower in mAFP vs standard of care (18 mm Hg [Q1-Q3: 14-22 mm Hg] vs 22 mm Hg [Q1-Q3: 20-26 mm Hg]; P < 0.001) and remained lower until 48 hours. The median first measured CPO was 0.56 W (95% CI: 0.41-0.76 W) in the control vs 0.68 W (95% CI: 0.51-0.85 W; P = 0.01), in the mAFP group, and remained higher in the mAFP group until 48 hours.

CONCLUSIONS

The mAFP reduces intrinsic mechanical work of the heart in STEMI-CS patients enrolled in the DanGer shock trial by reducing native CO, pulmonary pressures, and LV filling pressures while maintaining hydraulic power output delivered to the body by the heart and mAFP (CPO). (Danish Cardiogenic Shock Trial [DanShock]; NCT01633502).

Для цитирования: Møller Jacob Eifer, Beske Rasmus Paulin, Jensen Lisette Okkels, Eiskjær Hans, Mangner Norman, Polzin Amin, Schulze P Christian, Skurk Carsten, Nordbeck Peter, Schrage Benedikt, Panoulas Vasileios, Zimmer Sebastian, Schäfer Andreas, Werner Nikos, Holmvang Lene, Kjærgaard Jesper, Engstøm Thomas, Udesen Nanna Louise Junker, Schmidt Henrik, Junker Anders, Wachtell Kristian, Terkelsen Christian Juhl, Christensen Steffen, Linke Axel, Burkhoff Daniel, Hassager Christian, DanGer Shock Investigators. Effect of Microaxial Flow Pump on Hemodynamics in STEMI-Related Cardiogenic Shock.. Journal of the American College of Cardiology. 2025. DOI: 10.1016/j.jacc.2025.04.062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.